Zobrazeno 1 - 10
of 332
pro vyhledávání: '"Leung, K. K."'
Autor:
Alarcon, R., Aleksandrova, A., Baeßler, S., Beck, D. H., Bhattacharya, T., Blatnik, M., Bowles, T. J., Bowman, J. D., Brewington, J., Broussard, L. J., Bryant, A., Burdine, J. F., Caylor, J., Chen, Y., Choi, J. H., Christie, L., Chupp, T. E., Cianciolo, V., Cirigliano, V., Clayton, S. M., Collett, B., Crawford, C., Dekens, W., Demarteau, M., DeMille, D., Dodson, G., Filippone, B. W., Floyd, N., Fomin, N., Fry, J, Fuyuto, K., Gardner, S., Godri, R., Golub, R., Gonzalez, F., Greene, G. L., Gudkov, V., Gupta, R., Hamblen, J., Hayen, L., Hendrus, J C., Hickerson, K., Hills, F. B., Holley, A. T., Hoogerheide, S., Hubert, M., Huffman, P. R., Imam, S. K., Ito, T. M., Jin, L., Jones, G., Komives, A., Korobkina, E., Korsch, W., Leung, K. K. H., Liu, C. -Y., Liu, K. -F., Long, J. C., Mathews, D., Mendelsohn, A., Mereghetti, E., Mohanmurthy, P., Morris, C. L., Mueller, P., Mumm, H. P., Nelsen, A., Nicholson, A., Nico, J., O'Shaughnessy, C. M., Palamure, P. A., Pastore, S., Pattie Jr., R. W., Phan, N. S., Pioquinto, J. A., Plaster, B., Počanić, D., Rahangdale, H., Redwine, R., Reid, A., Salvat, D. J., Saunders, A., Schaper, D., Seng, C. -Y., Singh, M., Shindler, A., Snow, W. M., Tang, Z., Walker-Loud, A., Wong, D. K. -T., Wietfeldt, F., Young, A. R.
Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with
Externí odkaz:
http://arxiv.org/abs/2308.09059
Autor:
Li, X., Ahmed, M. W., Banu, A., Bartram, C., Crowe, B., Downie, E. J., Emamian, M., Feldman, G., Gao, H., Godagama, D., Grießhammer, H. W., Howell, C. R., Karwowski, H. J., Kendellen, D. P., Kovash, M. A., Leung, K. K. H., Markoff, D. M., McGovern, J. A., Mikhailov, S., Pywell, R. E., Sikora, M. H., Silano, J. A., Sosa, R. S., Spraker, M. C., Swift, G., Wallace, P., Weller, H. R., Whisnant, C. S., Wu, Y. K., Zhao, Z. W.
Publikováno v:
Phys. Rev. Lett. 128, 132502 (2022)
Differential cross sections for Compton scattering from the proton have been measured at scattering angles of $55^\circ$, $90^\circ$, and $125^\circ$ in the laboratory frame using quasimonoenergetic linearly (circularly) polarized photon beams with a
Externí odkaz:
http://arxiv.org/abs/2205.10533
Autor:
Li, X., Ahmed, M. W., Banu, A., Bartram, C., Crowe, B., Downie, E. J., Emamian, M., Feldman, G., Gao, H., Godagama, D., Grießhammer, H. W., Howell, C. R., Karwowski, H. J., Kendellen, D. P., Kovash, M. A., Leung, K. K. H., Markoff, D., Mikhailov, S., Pywell, R. E., Sikora, M. H., Silano, J. A., Sosa, R. S., Spraker, M. C., Swift, G., Wallace, P., Weller, H. R., Whisnant, C. S., Wu, Y. K., Zhao, Z. W.
Publikováno v:
Phys. Rev. C 101, 034618 (2020)
Differential cross sections for elastic Compton scattering from $^4$He have been measured with high statistical precision at the High Intensity $\gamma$-ray Source at laboratory scattering angles of $55^\circ$, $90^\circ$, and $125^\circ$ using a qua
Externí odkaz:
http://arxiv.org/abs/1912.06915
Autor:
Ahmed, M. W., Alarcon, R., Aleksandrova, A., Baessler, S., Barron-Palos, L., Bartoszek, L. M., Beck, D. H., Behzadipour, M., Berkutov, I., Bessuille, J., Blatnik, M., Broering, M., Broussard, L. J., Busch, M., Carr, R., Cianciolo, V., Clayton, S. M., Cooper, M. D., Crawford, C., Currie, S. A., Daurer, C., Dipert, R., Dow, K., Dutta, D., Efremenko, Y., Erickson, C. B., Filippone, B. W., Fomin, N., Gao, H., Golub, R., Gould, C. R., Greene, G., Haase, D. G., Hasell, D., Hawari, A. I., Hayden, M. E., Holley, A., Holt, R. J., Huffman, P. R., Ihloff, E., Imam, S. K., Ito, T. M., Karcz, M., Kelsey, J., Kendellen, D. P., Kim, Y. J., Korobkina, E., Korsch, W., Lamoreaux, S. K., Leggett, J., Leung, K. K. H., Lipman, A., Liu, C. Y., Long, J., MacDonald, S. W. T., Makela, M., Matlashov, A., Maxwell, J. D., Mendenhall, M., Meyer, H. O., Milner, R. G., Mueller, P. E., Nouri, N., O'Shaughnessy, C. M., Osthelder, C., Peng, J. C., Penttila, S. I., Phan, N. S., Plaster, B., Ramsey, J. C., Rao, T. M., Redwine, R. P., Reid, A., Saftah, A., Seidel, G. M., Silvera, I., Slutsky, S., Smith, E., Snow, W. M., Sondheim, W., Sosothikul, S., Stanislaus, T. D. S., Sun, X., Swank, C. M., Tang, Z., Dinani, R. Tavakoli, Tsentalovich, E., Vidal, C., Wei, W., White, C. R., Williamson, S. E., Yang, L., Yao, W., Young, A. R.
Publikováno v:
Journal of Instrumentation, Vol 14, P11017, 2019
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high d
Externí odkaz:
http://arxiv.org/abs/1908.09937
Autor:
Leung, K. K. H., Muhrer, G., Hügle, T., Ito, T. M., Lutz, E. M., Makela, M., Morris, C. L., Pattie, Jr., R. W., Saunders, A., Young, A. R.
The physics model of a next-generation spallation-driven high-current ultracold neutron (UCN) source capable of delivering an extracted UCN rate of around an-order-of-magnitude higher than the strongest proposed sources, and around three-orders-of-ma
Externí odkaz:
http://arxiv.org/abs/1905.09459
Autor:
Leung, K. K. H., Ahmed, M., Alarcon, R., Aleksandrova, A., Baeßler, S., Barrón-Palos, L., Bartoszek, L., Beck, D. H., Behzadipour, M., Bessuille, J., Blatnik, M. A., Broering, M., Broussard, L. J., Busch, M., Carr, R., Chu, P. -H., Cianciolo, V., Clayton, S. M., Cooper, M. D., Crawford, C., Currie, S. A., Daurer, C., Dipert, R., Dow, K., Dutta, D., Efremenko, Y., Erickson, C. B., Filippone, B. W., Fomin, N., Gao, H., Golub, R., Gould, C. R., Greene, G. L., Haase, D. G., Hasell, D., Hawari, A. I., Hayden, M. E., Holley, A. T., Holt, R. J., Huffman, P. R., Ihloff, E., Ito, T. M., Kelsey, J., Kim, Y. J., Koivuniemi, J., Korobkina, E., Korsch, W., Lamoreaux, S. K., Leggett, E., Lipman, A., Liu, C. -Y., Long, J., MacDonald, S. W. T., Makela, M., Matlashov, A., Maxwell, J., McCrea, M., Mendenhall, M., Meyer, H. O., Milner, R., Mueller, P., Nouri, N., O'Shaughnessy, C. M., Osthelder, C., Peng, J. -C., Penttila, S., Phan, N. S., Plaster, B., Ramsey, J., Rao, T., Redwine, R. P., Reid, A., Saftah, A., Seidel, G. M., Silvera, I. F., Slutsky, S., Smith, E., Snow, W. M., Sondheim, W., Sosothikul, S., Stanislaus, T. D. S., Sun, X., Swank, C. M., Tang, Z., Dinani, R. Tavakoli, Tsentalovich, E., Vidal, C., Wei, W., White, C. R., Williamson, S. E., Yang, L., Yao, W., Young, A. R.
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS)
Externí odkaz:
http://arxiv.org/abs/1903.02700
Publikováno v:
Phys. Rev. C 95, 035502 (2017)
We analyze the spin flip loss for ultracold neutrons in magnetic bottles of the type used in experiments aiming at a precise measurement of the neutron lifetime, extending the one-dimensional field model used previously by Steyerl $\textit{et al.}$ [
Externí odkaz:
http://arxiv.org/abs/1611.05037
Ultracold neutron (UCN) storage measurements were made in a trap constructed from a 1.3 T Halbach Octupole PErmanent (HOPE) magnet array aligned vertically, using the TES-port of the PF2 source at the Institut Laue-Langevin. A mechanical UCN valve at
Externí odkaz:
http://arxiv.org/abs/1606.00929
Autor:
Wei, Wanchun, Broussard, L. J., Hoffbauer, M. A., Makela, M., Morris, C. L., Tang, Z., Adamek, E. R., Callahan, N. B., Clayton, S. M., Cude-Woods, C., Currie, S., Dees, E. B., Ding, X., Geltenbort, P., Hickerson, K. P., Holley, A. T., Ito, T. M., Leung, K. K., Liu, C. -Y., Morley, D. J., Ortiz, Jose D., Pattie, Jr., R. W., Ramsey, J. C., Saunders, A., Seestrom, S. J., Sharapov, E. I., Sjue, S. K., Wexler, J., Womack, T. L., Young, A. R., Zeck, B. A., Wang, Zhehui
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A, vol. 830, 36-43 (2016)
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $\mu$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-el
Externí odkaz:
http://arxiv.org/abs/1604.08292
Publikováno v:
Phys. Rev. C 93, 025501 (2016)
Ultracold neutrons (UCNs) were produced in a 4 liter volume of superfluid helium using the PF1B cold neutron beam facility at the Institut Laue-Langevin and then extracted to a detector at room temperature. With a converter temperature of 1.08 K the
Externí odkaz:
http://arxiv.org/abs/1507.07475