Zobrazeno 1 - 10
of 129
pro vyhledávání: '"Leon R. Glicksman"'
Publikováno v:
Energies, Vol 16, Iss 17, p 6160 (2023)
Radiant floor heating systems have become a reference technology, but their use for cooling purposes has proven inconvenient in many applications due to their reduced cooling capacity and condensation issues. Nonetheless, potentialities and drawbacks
Externí odkaz:
https://doaj.org/article/018e3adcfaa5496a8cbd13737ac8014b
Publikováno v:
Science and Technology for the Built Environment. 26:1204-1215
A cooling tower (CT) model was built based on physical thermodynamics and heat and mass transfer principles using the effectiveness-NTU method for heat exchanger performance. The focus of the model...
Publikováno v:
Energy and Buildings. 201:163-173
The building sector of the U.S. currently consumes over 40% of the U.S. primary energy supply. Estimates suggest that between 5% and 30% of any building's annual energy consumption is unknowingly wasted due to pathologically malfunctioning lighting a
Publikováno v:
Proceeding of 5-6th Thermal and Fluids Engineering Conference (TFEC).
Publikováno v:
Research in Building Physics ISBN: 9781003078852
Research in Building Physics
Research in Building Physics
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::0290fcce45ae9f233b20e93f6fedb38a
https://doi.org/10.1201/9781003078852-70
https://doi.org/10.1201/9781003078852-70
Publikováno v:
Advances in Building Energy Research. 14:305-321
The building sector of the U.S. currently consumes over 40% of the U.S. primary energy supply. This paper presents analytical methods embodied within useful software tools to quickly identify and e...
Publikováno v:
Building and Environment. 205:108192
The challenge of comfort control within commercial and academic spaces was explored in an attempt to determine what would be the optimum location and type of measurement over different occupancies and different seasons of the year. A computational fl
Publikováno v:
Building and Environment
Although current industry guidelines to control the spread of aerosols such as SARS-CoV-2 (COVID-19) have adopted a six-foot (~1.8 m) spacing between individuals indoors, recent evidence suggests that longer range spread is also responsible for infec
Publikováno v:
Energy and Buildings. 138:530-538
Scale experiments that use water of different salinities to represent air at different temperatures are a common tool used to investigate room air ventilation. However, it has been shown that these experiments cannot replicate the effects of radiatio
Publikováno v:
Building and Environment. 112:99-114
Computational Fluid Dynamics simulations of a typical occupied office were performed to study the effects of ventilation parameters (supply momentum and heat gain intensity) and inlet geometry (height and area of the supply) on the temperature profil