Zobrazeno 1 - 10
of 64
pro vyhledávání: '"Lech Raczyński"'
Autor:
Paweł Moskal, Eryk Czerwiński, Juhi Raj, Steven D. Bass, Ermias Y. Beyene, Neha Chug, Aurélien Coussat, Catalina Curceanu, Meysam Dadgar, Manish Das, Kamil Dulski, Aleksander Gajos, Marek Gorgol, Beatrix C. Hiesmayr, Bożena Jasińska, Krzysztof Kacprzak, Tevfik Kaplanoglu, Łukasz Kapłon, Konrad Klimaszewski, Paweł Konieczka, Grzegorz Korcyl, Tomasz Kozik, Wojciech Krzemień, Deepak Kumar, Simbarashe Moyo, Wiktor Mryka, Szymon Niedźwiecki, Szymon Parzych, Elena Pérez del Río, Lech Raczyński, Sushil Sharma, Shivani Choudhary, Roman Y. Shopa, Michał Silarski, Magdalena Skurzok, Ewa Ł. Stępień, Pooja Tanty, Faranak Tayefi Ardebili, Keyvan Tayefi Ardebili, Kavya Valsan Eliyan, Wojciech Wiślicki
Publikováno v:
Nature Communications, Vol 15, Iss 1, Pp 1-10 (2024)
Abstract Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, perfo
Externí odkaz:
https://doaj.org/article/fb26ceb62fcb42b68d75a362620f14bd
Autor:
Paweł Konieczka, Lech Raczyński, Wojciech Wiślicki, Oleksandr Fedoruk, Konrad Klimaszewski, Przemysław Kopka, Wojciech Krzemień, Roman Y. Shopa, Jakub Baran, Aurélien Coussat, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Meysam Dadgar, Kamil Dulski, Aleksander Gajos, Beatrix C. Hiesmayr, Krzysztof Kacprzak, Łukasz Kapłon, Grzegorz Korcyl, Tomasz Kozik, Deepak Kumar, Szymon Niedźwiecki, Szymon Parzych, Elena Pérez del Río, Sushil Sharma, Shivani Shivani, Magdalena Skurzok, Ewa Łucja Stępień, Faranak Tayefi, Paweł Moskal
Publikováno v:
Mathematical Biosciences and Engineering, Vol 20, Iss 8, Pp 14938-14958 (2023)
In positron emission tomography (PET) studies, convolutional neural networks (CNNs) may be applied directly to the reconstructed distribution of radioactive tracers injected into the patient's body, as a pattern recognition tool. Nonetheless, unproce
Externí odkaz:
https://doaj.org/article/29417b65546c4e0896ca7b48bcc241cd
Autor:
Anna Wieczorek, Kamil Dulski, Szymon Niedźwiecki, Dominika Alfs, Piotr Białas, Catalina Curceanu, Eryk Czerwiński, Andrzej Danel, Aleksander Gajos, Bartosz Głowacz, Marek Gorgol, Beatrix Hiesmayr, Bożena Jasińska, Krzysztof Kacprzak, Daria Kamińska, Łukasz Kapłon, Andrzej Kochanowski, Grzegorz Korcyl, Paweł Kowalski, Tomasz Kozik, Wojciech Krzemień, Ewelina Kubicz, Mateusz Kucharek, Muhsin Mohammed, Monika Pawlik-Niedźwiecka, Marek Pałka, Lech Raczyński, Zbigniew Rudy, Oleksandr Rundel, Neha G Sharma, Michał Silarski, Tomasz Uchacz, Wojciech Wiślicki, Bożena Zgardzińska, Marcin Zieliński, Paweł Moskal
Publikováno v:
PLoS ONE, Vol 12, Iss 11, p e0186728 (2017)
A novel plastic scintillator is developed for the application in the digital positron emission tomography (PET). The novelty of the concept lies in application of the 2-(4-styrylphenyl)benzoxazole as a wavelength shifter. The substance has not been u
Externí odkaz:
https://doaj.org/article/e963cf55995c44119c43e5ed5bf37d3b
Autor:
Lech Raczyński
Positron Emission Tomography (PET) is a key technique in the medical imaging area, which allows to diagnose the organism functions and to track the tumor changes. In PET measurement the patient is injected with radiotracer, containing a large number
Autor:
Sz. Niedzwiecki, Muhsin Mohammed, J. Raj, D. Kisielewska, L. Kaplon, M. Bała, G. Korcyl, R. Y. Shopa, J. Chhokar, Tomasz Bednarski, M. Dadgar, Shivani, Bożena Jasińska, W. Wislicki, Konrad Klimaszewski, Magdalena Skurzok, M. Pawlik-Niedzwiecka, N. Krawczyk, Bożena Zgardzińska, Aleksander Gajos, Marek Palka, E. L. Stepien, Sushil K. Sharma, Wojciech Krzemien, Paweł Kowalski, Tomasz Kozik, Catalina Curceanu, H. Karimi, Kamil Dulski, Marek Gorgol, Paweł Moskal, Lech Raczyński, Ewelina Kubicz, Michał Silarski, Eryk Czerwiński, R. Del Grande, K. Kacprzak, N. Gupta-Sharma, Beatrix C. Hiesmayr
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 70:1-10
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators,
Autor:
Damian Borys, Jakub Baran, Karol Brzeziński, Jan Gajewski, Neha Chug, Aurelien Coussat, Eryk Czerwiński, Meysam Dadgar, Kamil Dulski, Kavya V Eliyan, Aleksander Gajos, Krzysztof Kacprzak, Łukasz Kapłon, Konrad Klimaszewski, Paweł Konieczka, Renata Kopeć, Grzegorz Korcyl, Tomasz Kozik, Wojciech Krzemień, Deepak Kumar, Antony J Lomax, Keegan McNamara, Szymon Niedźwiecki, Paweł Olko, Dominik Panek, Szymon Parzych, Elena Perez del Rio, Lech Raczyński, Sushil Sharma, null Shivani, Roman Y Shopa, Tomasz Skóra, Magdalena Skurzok, Paulina Stasica, Ewa Ł Stępień, Keyvan Tayefi, Faranak Tayefi, Damien C Weber, Carla Winterhalter, Wojciech Wiślicki, Paweł Moskal, Antoni Rucinski
Publikováno v:
Borys, Damian; Baran, Jakub; Brzezinski, Karol W; Gajewski, Jan; Chug, Neha; Coussat, Aurelien; Czerwiński, Eryk; Dadgar, Meysam; Dulski, Kamil; Eliyan, Kavya Valsan; Gajos, Aleksander; Kacprzak, Krzysztof; Kapłon, Łukasz; Klimaszewski, Konrad; Konieczka, Paweł; Kopec, Renata; Korcyl, Grzegorz; Kozik, Tomasz; Krzemień, Wojciech; Kumar, Deepak; ... (2022). ProTheRaMon-a GATE simulation framework for proton therapy range monitoring using PET imaging. (In Press). Physics in medicine and biology Institute of Physics Publishing IOP 10.1088/1361-6560/ac944c
Objective.This paper reports on the implementation and shows examples of the use of theProTheRaMonframework for simulating the delivery of proton therapy treatment plans and range monitoring using positron emission tomography (PET).ProTheRaMonoffers
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::699235ac4d070dc8080b41c8845ede38
https://ruj.uj.edu.pl/xmlui/handle/item/303956
https://ruj.uj.edu.pl/xmlui/handle/item/303956
Autor:
Konrad Klimaszewski, Grzegorz Grudzień, Ewa Stępień, J. Raj, G. Korcyl, K. Kacprzak, Aleksander Gajos, R. Y. Shopa, Paweł Kowalski, N. Chug, Magdalena Skurzok, Wojciech Krzemien, Beatrix C. Hiesmayr, Monika Pawlik-Niedźwiecka, F. Tayefi, Lech Raczyński, Sushil K. Sharma, Shivani, Łukasz Kapłon, Eryk Czerwiński, Catalina Curceanu, Szymon Niedźwiecki, Piotr Małczak, Michał Silarski, Michał Pędziwiatr, Ewelina Kubicz, H. Karimi, J. Gajewski, N. Krawczyk, Wojciech Wiślicki, Antoni Rucinski, Paweł Moskal, Monika Szczepanek, Tomasz Kozik, Kamil Dulski, M. Dadgar
Publikováno v:
Science advances. 7(42)
In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emis
Autor:
Pawel Moskal, Aleksander Gajos, Muhsin Mohammed, Jyoti Chhokar, Neha Chug, Catalina Curceanu, Eryk Czerwiński, Meysam Dadgar, Kamil Dulski, Marek Gorgol, Jacek Goworek, Beatrix Hiesmayr, Bożena Jasińska, Łukasz Kapłon, Hanieh Karimi, Daria Kisielewska, Konrad Klimaszewski, Grzegorz Korcyl, Paweł Kowalski, Nikodem Krawczyk, Wojciech Krzemień, Tomasz Kozik, Ewelina Kubicz, Szymon Niedźwiecki, Szymon Parzych, Monika Pawlik-Niedźwiecka, Lech Raczyński, Juhi Raj, Sushil Sharma, Shivani Choudhary, Roman Shopa, Andrzej Sienkiewicz, Michał Silarski, Magdalena Skurzok, Ewa Stepien, Faranak Tayefi, Wojciech Wiślicki
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron–positron bound state (posit
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::438425c357bcfcfb2b2f8aa6429b4faf
https://doi.org/10.21203/rs.3.rs-150089/v1
https://doi.org/10.21203/rs.3.rs-150089/v1
Autor:
Muhsin Mohammed, Monika Pawlik-Niedźwiecka, Tomasz Kozik, S. S. Choudhary, Szymon Parzych, K. Kacprzak, R. Y. Shopa, Catalina Curceanu, Aleksander Gajos, Eryk Czerwiński, Lech Raczyński, J. Chhokar, Szymon Niedźwiecki, Wojciech Wiślicki, Marek Gorgol, Ewa Stępień, Michał Silarski, Wojciech Krzemien, Andrzej Sienkiewicz, Bożena Jasińska, Grzegorz Korcyl, Sushil K. Sharma, Paweł Moskal, F. Tayefi, N. Chug, Łukasz Kapłon, Konrad Klimaszewski, H. Karimi, Magdalena Skurzok, J. Raj, Ewelina Kubicz, Paweł Kowalski, N. Krawczyk, Kamil Dulski, Jacek Goworek, D. Kisielewska, M. Dadgar, Beatrix C. Hiesmayr
Publikováno v:
Nature Communications, Vol 12, Iss 1, Pp 1-9 (2021)
Nature Communications
Nature Communications
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positro
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::8b6f9cef10301ddf231f4b8df237fc91
https://ruj.uj.edu.pl/xmlui/handle/item/283485
https://ruj.uj.edu.pl/xmlui/handle/item/283485
Autor:
Beatrix C. Hiesmayr, Lech Raczyński, Shivani, R. Y. Shopa, F. Tayefi, Kamil Dulski, N. Chug, Paweł Moskal, Aleksander Gajos, E.Ł. Stȩpień, Sushil K. Sharma, Eryk Czerwiński, P. Kopka, K. Kacprzak, Łukasz Kapłon, Catalina Curceanu, Paweł Kowalski, Wojciech Wiślicki, Grzegorz Korcyl, J. Raj, Wojciech Krzemien, Sz. Niedźwiecki, Ewelina Kubicz, Konrad Klimaszewski, D. Kisielewska, M. Dadgar, N. Krawczyk
We perform a parametric study of the newly developed time-of-flight (TOF) image reconstruction algorithm, proposed for the real-time imaging in total-body Jagiellonian PET (J-PET) scanners. The asymmetric 3D filtering kernel is applied at each most l
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c7616acc21fd7f98b20e2aa0d0514270