Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Lars G. Andersson"'
Publikováno v:
Clinical Physiology and Functional Imaging. 30:279-284
P>Background: PET using 1-11C-acetate (ACE-PET) applied at rest is used for measuring absolute myocardial blood flow (MBF) and oxidative metabolic rate (k(mono)). We evaluated the feasibility of quantitative ACE-PET during exercise. Methods: Five end
Autor:
Christian Putensen, Lars G. Andersson, José Hinz, Hermann Wrigge, Enn Maripuu, Jörg Zinserling, Göran Hedenstierna, Peter J. Neumann
Publikováno v:
Critical Care Medicine. 33:1090-1095
In acute respiratory failure, gas exchange improves with spontaneous breathing during airway pressure release ventilation (APRV). The mechanisms for this improvement are not fully clear. We have shown that APRV with spontaneous breathing reopens nona
Publikováno v:
Clinical Oral Implants Research. 14:714-719
The aims of this study were to examine whether viewers agreed on details seen in direct (real time) digital and conventional film radiographs of implants, and whether there were differences in agreement between the systems. Intra-oral radiographs of
Autor:
Hermann Wrigge, Lars G. Andersson, Göran Hedenstierna, Peter J. Neumann, Taras Dudykevych, José Hinz, Hilmar Burchardi
Publikováno v:
Chest. 124:314-322
Study objective: The validation of electrical impedance tomography (EIT) for measuring regional ventilation distribution by comparing it with single photon emission CT (SPECT) scanning. Design: Randomized, prospective animal study. Settings: Animal l
Publikováno v:
Clinical physiology and functional imaging. 30(4)
PET using 1-(11)C-acetate (ACE-PET) applied at rest is used for measuring absolute myocardial blood flow (MBF) and oxidative metabolic rate (k(mono)). We evaluated the feasibility of quantitative ACE-PET during exercise.Five endurance athletes underw
Publikováno v:
Clinical oral implants research. 14(6)
The aims of this study were to examine whether viewers agreed on details seen in direct (real time) digital and conventional film radiographs of implants, and whether there were differences in agreement between the systems. Intra-oral radiographs of
Autor:
Jan Erik Berglund, Enn Maripu, Lars G. Andersson, Anders Magnusson, Göran Hedenstierna, Peter Neumann
Publikováno v:
American journal of respiratory and critical care medicine. 161(5)
Continuous as well as cyclic (with each expiration) lung collapse in acute respiratory failure can be reduced by positive end-expiratory pressure (PEEP) or short expiration times, as in inverse ratio ventilation (IRV). In 20 pigs with oleic acid-indu