Zobrazeno 1 - 10
of 204
pro vyhledávání: '"Larry E. Antonuk"'
Publikováno v:
Medical Imaging 2022: Physics of Medical Imaging.
Publikováno v:
Medical Physics. 47:3972-3983
Purpose In the spirit of overcoming the signal-to-noise limitations of active matrix, flat-panel imagers (AMFPIs) which employ array circuits based on a-Si:H thin-film transistors (TFTs), an empirical investigation of the noise properties of prototyp
Publikováno v:
Physics in Medicine & Biology. 68:025023
Objective. Polycrystalline mercuric iodide photoconductive converters fabricated using particle-in-binder techniques (PIB HgI2) provide significantly more detected charge per x-ray interaction than from a-Se and CsI:Tl converters commonly used with a
Publikováno v:
Physics in medicine and biology. 66(15)
Active matrix, flat-panel imagers (AMFPIs) suffer from decreased detective quantum efficiency under conditions of low dose per image frame (such as for digital breast tomosynthesis, fluoroscopy and cone-beam CT) due to low signal compared to the addi
Autor:
Qihua Zhao, Larry E. Antonuk, Ian A. Cunningham, Youcef El-Mohri, Liuxing Shen, Albert K. Liang
Publikováno v:
Medical Imaging 2021: Physics of Medical Imaging.
The DQE performance of active matrix flat-panel imagers (AMFPIs) degrades under low dose conditions – such as those encountered in digital breast tomosynthesis where electronic additive noise becomes comparable to imaging signal. Compared to commer
Publikováno v:
Medical Imaging 2020: Physics of Medical Imaging.
For active matrix flat-panel imagers (AMFPIs), relatively high levels of additive noise compared to the average imaging signal per interacting x-ray limits DQE under conditions of low dose per frame – degrading imaging performance in applications s
Publikováno v:
Medical Physics. 45:4418-4429
PURPOSE Photon counting arrays (PCAs), capable of measuring the spectral information of individual x-ray photons and recording that information digitally, provide a number of advantages compared to conventional, energy-integrating active matrix flat-
Publikováno v:
Physics in Medicine & Biology. 66:155019
Active matrix, flat-panel imagers (AMFPIs) suffer from decreased detective quantum efficiency under conditions of low dose per image frame (such as for digital breast tomosynthesis, fluoroscopy and cone-beam CT) due to low signal compared to the addi
Publikováno v:
Medical Physics. 44:3491-3503
Purpose Active matrix flat-panel imagers, which typically incorporate a pixelated array with one a-Si:H thin-film transistor (TFT) per pixel, have become ubiquitous by virtue of many advantages, including large monolithic construction, radiation tole
Publikováno v:
Medical Imaging 2019: Physics of Medical Imaging.
Photon counting detectors are of increasing interest for clinical imaging. By measuring and digitally recording the deposited energy of each detected x-ray photon, these detectors can decrease the effect of electronic readout noise and Swank noise, p