Zobrazeno 1 - 10
of 24
pro vyhledávání: '"L.G. Atencio"'
Autor:
W.W. Kinnison, M.W. Rawool-Sullivan, M. L. Brooks, P. L. McGaughey, V. Armijo, W. E. Sondheim, Christopher Morris, L.G. Atencio, S. J. Seestrom, D. M. Lee
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 379:243-246
We describe a technique for etching electrically isolated strips onto metalized Mylar surfaces suitable for strip cathode readout multiwire chambers. Cathode planes created using this technique are much thinner than those made using previously descri
Autor:
D. Clark, J. Behrendt, D. E. Fields, W. E. Sondheim, J. Lowe, J. Stuart, M. L. Brooks, B. Bassalleck, D. M. Lee, X.F. Wang, S. Klinksiek, V. Armijo, B.V. Dinesh, L.G. Atencio
Publikováno v:
1996 IEEE Nuclear Science Symposium. Conference Record.
The muon tracking system for the PHENIX detector uses cathode strip chambers (CSC) for the tracking detectors. These detectors must provide 58 micron resolution at each station to give satisfactory mass resolution of the vector mesons. Station 1 must
Autor:
Z. Chen, G. Hart, V. Armijo, M.M. Murray, L.G. Atencio, H. Matousek, Christopher Morris, D. E. Fields, Z. Wang, W. W. Kinnison, D. M. Lee, Y. Wang, B.V. Dinesh, D. Clark, W. E. Sondheim, M. L. Brooks
Publikováno v:
1996 IEEE Nuclear Science Symposium. Conference Record.
The muon tracking system for the PHENIX detector at RHIC uses cathode strip chambers (CSC) for the tracking detectors. These detectors must provide 100 /spl mu/m resolution per measurement plane to give satisfactory mass resolution of the vector meso
Autor:
A. Bridge, G. Hart, T. Mottershead, Christopher Morris, V. Armijo, L.G. Atencio, George J. Yates, A. Gavron, J. D. Zumbro, K. B. Morley
Publikováno v:
SPIE Proceedings.
We describe an integrating cathode-pad read-out wire chamber for imaging high energy neutrons. This technology allows construction of a detector with a wide dynamic range, which is gatable, easily read out, and provides millimeter scale resolution. R
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 334:643-644
Autor:
G. P. A. Berg, B. Brinkmöller, J. G. M. Römer, L. Zemlo, P. von Rossen, D. Paul, G. Hlawatsch, Christopher Morris, S. J. Seestrom-Morris, T. Sagefka, L.G. Atencio, M. Rogge, C.F. Moore, J. Meissburger, P. von Brentano
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 242:95-102
Two delay-line readout drift chambers with an active area of 90 cm by 7 cm are now in use as focal plane detectors at the high resolution spectrometer Big Karl. The position resolution is better than 0.2 mm fwhm with detector efficiencies exceeding 9
Publikováno v:
Nuclear Instruments and Methods in Physics Research. 203:415-418
The design and performance of a multi-wire proportional for counter 2–6 keV X-rays are presented. We also report on the use of this detector in a Bragg crystal spectrometer in the application of X-ray diagnostics of the plasma of the Aleator C toka
Publikováno v:
Nuclear Instruments and Methods in Physics Research. 188:491-494
A multiwire proportional counter is described which yields time, position, and angle information. We report a measured time resolution of 2 ns fwhm, and an estimated position resolution of 0.1 mm.
Publikováno v:
Nuclear Instruments and Methods in Physics Research. 187:381-386
Delay-line readout multiwire gas proportional chambers have been constructed that use drift time information to interpolate between anode wires. Position resolutions over the entire active area of the chamber of 150 μm fwhm are routinely obtained fo