Autor:
J A Cattell, L R Stover, Paul F Corey, J H Pendergrass, R. W. Trimmer, J P Albarella, R J Tyhach, A. E. Burkhardt, A C Skjold, M P Farinelli
Publikováno v:
Clinical Chemistry. 33:1242-1245
A new reagent strip for the determination of leukocytes in urine (LEUKOSTIX; Ames) is described. The test is based on the esterase activity in leukocytes as a marker. Upon contact between the reagent matrix and a urine containing leukocytes, an amino
Autor:
L R Stover, R H White-Stevens
Publikováno v:
Clinical Chemistry. 28:589-595
Ascorbic acid hampers some test systems based on use of peroxidase (EC 1.11.1.7) and redox indicators, by producing a lag time in color development. With reversible indicators, no color development occurs during the ascorbic acid lag time. With oxida
Publikováno v:
Journal of Applied Polymer Science. 22:2019-2024
The tensile properties of polycarbonate were investigated for specimens subjected to three sterilization procedures—(autoclaving, gassing, and gamma irradiation). Generally the tensile modulus decreased and the percent elongation at yield increased
Publikováno v:
The Journal of Organic Chemistry. 50:3612-3614
Publikováno v:
Clinical Chemistry. 32:1400-1402
The control system described here is used to monitor the performance of urinary reagent-strip tests for leukocytes. The presence of leukocyte esterase in the urine is used as a marker for leukocytes in urine. The control system is based on sonicated
Publikováno v:
Chemischer Informationsdienst. 17
Autor:
A C, Skjold, L R, Stover, J H, Pendergrass, P F, Corey, J A, Cattell, A E, Burkhardt, M P, Farinelli, R J, Tyhach, J P, Albarella, R W, Trimmer
Publikováno v:
Clinical chemistry. 33(7)
A new reagent strip for the determination of leukocytes in urine (LEUKOSTIX; Ames) is described. The test is based on the esterase activity in leukocytes as a marker. Upon contact between the reagent matrix and a urine containing leukocytes, an amino
Publikováno v:
Clinical chemistry. 32(7)
The control system described here is used to monitor the performance of urinary reagent-strip tests for leukocytes. The presence of leukocyte esterase in the urine is used as a marker for leukocytes in urine. The control system is based on sonicated
Autor:
R H, White-Stevens, L R, Stover
Publikováno v:
Clinical chemistry. 28(4 Pt 1)
Ascorbic acid hampers some test systems based on use of peroxidase (EC 1.11.1.7) and redox indicators, by producing a lag time in color development. With reversible indicators, no color development occurs during the ascorbic acid lag time. With oxida
Publikováno v:
Clinical chemistry. 26(9)