Publikováno v:
Atomic Energy. 77:580-587
During the accident in the fourth power-generating unit of the Chernobyl nuclear power plant complicated spatially distributed processes (neutron-physical, thermohydrodynamic, chemical, and thermomechanical) were focused and became intertwined. This
Publikováno v:
Soviet Atomic Energy. 71:615-621
Autor:
L. N. Podlazov, N. L. Chichulin
Publikováno v:
Atomic Energy; Jan2004, Vol. 96 Issue 1, p22-25, 4p
Publikováno v:
Soviet Atomic Energy. 60:107-112
In creating an overcompensation system it is necessary to determine the number and distribution of overcompensation (OC) rods relative to the rods of the regulating system, as well as signals which will actuate them. This paper solves these problems
Publikováno v:
Soviet Atomic Energy. 49:813-820
The development of the theoretical principles of construction of these systems and of sufficiently detailed nonlinear dynamic numerical models of a power-generation unit with an RBMK reactor have allowed a consistent procedure to be produced for the
Autor:
Yu. I. Mityaev, A. G. Sheikman, V. G. Zakharov, P. A. Gavrilov, V.I. Mikhan, G. A. Zvereva, T. D. Ogina, V. D. Kozyrev, N. Z. Rybakov, L. N. Podlazov, S. V. Shirokov, A. I. Ionov
Publikováno v:
Soviet Atomic Energy. 54:103-106
An analysis of the dynamics of the processes in the case of emergency situations with shutdown of the station and depressurization of the circulatory circuit allow the conditions of heat removal in the core to be determined in these regimes (reserves
Autor:
B. M. Svecharevskii, L. N. Podlazov, B. A. Vorontsov, I. Ya. Emel'yanov, V. I. Ryabov, V. D. Rogova
Publikováno v:
Soviet Atomic Energy. 48:161-164
Studies of the neutron noise of the RBMK-1000 can be made on the basis of the existing regular CSS equipment. In studying the neutron noise it was revealed that in the frequency range 0.021–0.022 Hz the spectral characteristic displays a resonance
Publikováno v:
Soviet Atomic Energy. 48:302-305
A method has been developed for calculating the stability of a power reactor with any stationary power distribution Φ0(r); tables have been formulated for the values of the parameters that can be used to determine the instability buildup period for
Publikováno v:
Soviet Atomic Energy. 46:90-96
An asymmetric regulating system with scattered data units and regulating rods stabilizes an energy distribution which with no external feedback would be essentially unstable. However, with a system of reactor control constructed solely on the basis o
Autor:
A. N. Aleksakov, V. M. Panin, I. Ya. Emel'yanov, V. D. Rogova, L. N. Podlazov, E. V. Nikolaev
Publikováno v:
Soviet Atomic Energy. 53:747-752