Publikováno v:
Synthetic Metals. 91:69-72
A scanning tunneling microscope (STM) is used to generate electroluminescence from thin films of tris(8-hydroxyquinolato) aluminum (Alq 3 ) deposited on Au(111) substrates. The emission spectra are highly dependent on the local structural features of
Publikováno v:
Review of Scientific Instruments. 66:97-100
To achieve both high stability for scanning tunneling microscopy (STM) measurements and well‐defined tunnel current localization even on very rough surfaces, we have developed a new electrochemical procedure using CaCl2 etching and H2SO4 micro poli
Publikováno v:
BMC Genomics. 9/18/2024, Vol. 25 Issue 1, p1-13. 13p.
Publikováno v:
Review of Scientific Instruments. 64:1489-1494
To achieve both high stability during scanning tunneling microscopy (STM) measurements at atomic resolution and long‐range imaging of nonhomogeneous samples, we have developed a fully 2D vertical inertial nanopositioner which allows tunneling tip d
Publikováno v:
AIP Conference Proceedings.
An Atomic Force Microscope (AFM) operating at low temperature (82 K) and under UltraHigh Vacuum (UHV) conditions (10−7 −10−9 mbar) is presented. The AFM uses the laser beam deflection method and it was developed for studying biological samples.
Publikováno v:
Vacuum. 41:1714-1715
We present measurements of the mechanical response function for the prototype of a Scanning Tunneling Microscope (STM) developed in Namur. The results allow an estimate of the noise level, in agreement with the tunneling-current data and consistent w
Publikováno v:
Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures. 13:1325
To induce modifications of gold (111) surface using a scanning tunneling microscope, we have developed new electrochemical procedures to obtain very sharp gold and platinum tips. The resulting geometry is very reproducible and the mean curvature radi
Publikováno v:
Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures. 9:655
We perform here a complete determination of the relation between applied voltage and displacement for a tripod piezoceramic scanning tunneling microscope (STM) scanner unit. The absolute calibration is obtained in two steps. First the gap between two
Publikováno v:
Molecular Biomedicine; 10/10/2024, Vol. 5 Issue 1, p1-32, 32p
Autor:
Gödrich, Sebastian, Brodoceanu, Daniel, Kuznetsov, Volodymyr, Kraus, Tobias, Papastavrou, Georg
Publikováno v:
Advanced Materials Interfaces; 8/5/2024, Vol. 11 Issue 22, p1-9, 9p