Zobrazeno 1 - 10
of 131
pro vyhledávání: '"L. Fritzsch"'
Autor:
Louis Polomé, H.-G. Meyer, M. Meyer, Ronny Stolz, L. Fritzsch, Vyacheslav Zakosarenko, M. Schulz, A. Chwala, A Rompel
Publikováno v:
ASEG Extended Abstracts. 2012:1-4
IPHT Jena and Supracon AG develop and fabricate full tensor magnetic gradiometer (FTMG) systems, based on low-temperature-superconducting (LTS) planar-type SQUID (Superconducting Quantum Interference Device) gradiometers of first order. The systems a
Autor:
Vyacheslav Zakosarenko, L. Fritzsch, Ronny Stolz, Matthias Schmelz, M. Meyer, H.-G. Meyer, Solveig Anders, Michael Mück, T. Schönau
Publikováno v:
Physica C: Superconductivity and its Applications. 482:27-32
We review the development of low parasitic capacitance sub-micrometer cross-type Josephson tunnel junctions for their use in highly sensitive and field-stable SQUID magnetometers. The potential of such junctions is shown on I – V characteristics as
Autor:
H. Roth, H.-G. Meyer, Solveig Anders, Ronny Stolz, L. Fritzsch, Matthias Schmelz, Vyacheslav Zakosarenko
Publikováno v:
Physica C: Superconductivity. 476:77-80
We report on a new method suitable for the fabrication of highly sensitive SQUID magnetometers exhibiting very small effective areas. In contrast to commonly used approaches, which mostly make use of constrictions in a superconducting material to for
Publikováno v:
Encyclopedia of Applied Physics
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::90a07d3f8bb1c995e00845e20dcfefa3
https://doi.org/10.1002/3527600434.eap744
https://doi.org/10.1002/3527600434.eap744
Autor:
Tengming Shen, Günter Fuchs, Claudia Cantoni, Frank N. Werfel, Cesar Luongo, Gunter Kaiser, Mariappan Parans Paranthaman, Andreas Kade, J. Kunert, Keiichi Tanabe, Luca Bottura, Liliana Stan, Quanxi Jia, Gernot Krabbes, Andreas Erb, Hans-Georg Meyer, Roger Wördenweber, L. Fritzsch, Matthias Schmelz, G. Oelsner, Tolga Aytug, Gunar Schroeder, Eric E. Hellstrom, Jianyi Jiang, Solveig Anders, Wolf‐Rüdiger Canders
Publikováno v:
Applied Superconductivity : Handbook on Devices and Applications
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::a05b9f222194a082b3efbed57331d4c1
https://doi.org/10.1002/9783527670635.ch3
https://doi.org/10.1002/9783527670635.ch3
Publikováno v:
IEEE Transactions on Appiled Superconductivity. 15:773-776
We designed first-order integrated planar SQUID gradiometers especially for readout of signals from magnetic micro-calorimeters used for the detection of single x-ray quanta. These SQUIDs must operate in magnetic fields up to 5 mT and at temperatures
Autor:
Ronny Stolz, J. Kunert, Vyacheslav Zakosarenko, H.-G. Meyer, R. Boucher, T. May, L. Fritzsch, W. Esch, Ernst Kreysa, Solveig Anders
Publikováno v:
IEEE Transactions on Appiled Superconductivity. 15:537-540
We present the first steps toward a 288 pixel sub-millimeter wavelength bolometer camera. We have used bolometers of the transition edge type, choosing a thermometer made of a proximity bilayer of Mo and the alloy Au/Pd with a designed transition tem
Autor:
Ronny Stolz, H.-G. Meyer, L. Fritzsch, Robert H. Kraus, A.N. Matlachov, Vyacheslav Zakosarenko, Michelle A. Espy, Petr Volegov
Publikováno v:
IEEE Transactions on Appiled Superconductivity. 15:676-679
We have built and demonstrated a simple system with open geometry that measures biomagnetic signals such as magnetoencephalogram (MEG), magnetocardiogram (MCG) and magnetomyogram (MMG) simultaneously with low field nuclear magnetic resonance (NMR) fr
Publikováno v:
Superconductor Science and Technology. 16:1404-1407
First-order integrated planar SQUID gradiometers with pick-up loops of 40 µm in diameter and a baseline of 200 µm were designed specially for the readout of signals from magnetic micro-calorimeters. The SQUID has to operate in magnetic fields up to
Publikováno v:
IEEE Transactions on Appiled Superconductivity. 13:142-145
We have developed a very simple method for manufacturing submicrometer Josephson junctions (JJs) based on niobium and titanium layers. Together with the use of a microwave circuit consisting of modified coplanar strips this type of JJs offers the pos