Zobrazeno 1 - 10
of 17
pro vyhledávání: '"L W, Hedlund"'
Publikováno v:
Magnetic resonance in medicine. 45(3)
Using in vivo magnetic resonance microscopy, registered (1)H and hyperpolarized (3)He images of the rat lung were obtained with a resolution of 0.098 x 0.098 x 0.469 mm (4.5 x 10(-3) mm(3)). The requisite stability and SNR was achieved through an int
Publikováno v:
Magnetic resonance in medicine. 45(3)
Hyperpolarized (3)He spin-lattice relaxation was investigated in the guinea pig lung using spectroscopy and imaging techniques with a repetitive RF pulse series. T(1) was dominated by interactions with oxygen and was used to measure the alveolar O(2)
Publikováno v:
NMR in biomedicine. 13(4)
Hyperpolarized helium (HP (3)He) is useful for direct MR imaging of the gas spaces of small animal lungs. Previously, breaths of 100% HP (3)He were alternated with breaths of air to maximize helium signal in the lungs and to minimize the depolarizing
Publikováno v:
Magnetic resonance in medicine. 42(4)
In imaging of hyperpolarized noble gases, a knowledge of the diffusion coefficient (D) is important both as a contrast mechanism and in the design of pulse sequences. We have made diffusion coefficient maps of both hyperpolarized (3)He and (129)Xe in
Autor:
X J, Chen, H E, Möller, M S, Chawla, G P, Cofer, B, Driehuys, L W, Hedlund, J R, MacFall, G A, Johnson
Publikováno v:
Magnetic resonance in medicine. 42(4)
The transverse relaxation time, T *(2), of hyperpolarized (HP) gas in the lung in vivo is an important parameter for pulse sequence optimization and image contrast. We obtained T *(2) maps of HP (3)He and (129)Xe in guinea pig lungs (n = 17) and in h
Publikováno v:
Regional anesthesia and pain medicine. 24(4)
Pathophysiologic mechanisms underlying persistent neurologic deficits after continuous spinal anesthesia using hyperbaric 5% lidocaine are still not well understood. It has been suggested that high-dose intrathecal lidocaine induces irreversible cond
Publikováno v:
Magnetic resonance in medicine. 41(5)
Hyperpolarized (HP) 129Xe can be dissolved in biologically compatible lipid emulsions while maintaining sufficient polarization for in vivo vascular imaging. For xenon in Intralipid 30%, in vitro spectroscopy at 2 T yielded a chemical shift of 197 +/
Autor:
H E, Möller, X J, Chen, M S, Chawla, G P, Cofer, B, Driehuys, L W, Hedlund, S A, Suddarth, G A, Johnson
Publikováno v:
Magnetic resonance in medicine. 41(4)
Three-dimensional magnetic resonance images of the guinea pig lung were acquired in vivo using hyperpolarized (HP) noble gases and radial projection encoding (PE). Results obtained with 3He (voxel size 17 microl) demonstrated high image quality showi
Autor:
M, Viallon, G P, Cofer, S A, Suddarth, H E, Möller, X J, Chen, M S, Chawla, L W, Hedlund, Y, Crémillieux, G A, Johnson
Publikováno v:
Magnetic resonance in medicine. 41(4)
A new strategy designed to provide functional magnetic resonance images of the lung in small animals at microscopic resolution using hyperpolarized 3He is described. The pulse sequence is based on a combination of radial acquisition (RA) and CINE tec
Autor:
J R, Miller, S E, Hurlston, Q Y, Ma, D W, Face, D J, Kountz, J R, MacFall, L W, Hedlund, G A, Johnson
Publikováno v:
Magnetic resonance in medicine. 41(1)
The use of a high-temperature superconducting probe for in vivo magnetic resonance microscopy at 2 T is described. To evaluate the performance of the probe, a series of SNR comparisons are carried out. The SNR increased by a factor of 3.7 compared wi