Zobrazeno 1 - 10
of 351
pro vyhledávání: '"L M, Fraile"'
Autor:
S. E. A. Orrigo, J. L. Tain, N. Mont-Geli, A. Tarifeño-Saldivia, L. M. Fraile, M. Grieger, J. Agramunt, A. Algora, D. Bemmerer, F. Calviño, G. Cortés, A. De Blas, I. Dillmann, A. Domínguez Bugarín, R. García, E. Nacher, A. Tolosa-Delgado
Publikováno v:
European Physical Journal C: Particles and Fields, Vol 82, Iss 9, Pp 1-11 (2022)
Abstract We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign w
Externí odkaz:
https://doaj.org/article/4bb197deaa034bfb8de84f4c8a8115d7
11 pages, 7 figures
Ground and isomeric states of the neutron-deficient odd-A isotopes 183Hg, 185Hg, and 187Hg are described from a microscopic calculation based on a self-consistent, axially deformed Hartree-Fock mean field with the Skyrme func
Ground and isomeric states of the neutron-deficient odd-A isotopes 183Hg, 185Hg, and 187Hg are described from a microscopic calculation based on a self-consistent, axially deformed Hartree-Fock mean field with the Skyrme func
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::2cb7ea1f89eb516855b6b491e6b9e93e
https://eprints.ucm.es/id/eprint/76469/
https://eprints.ucm.es/id/eprint/76469/
Autor:
D. Kumar, T. Bhattacharjee, S. S. Alam, S. Basak, L. Gerhard, L. Knafla, A. Esmaylzadeh, M. Ley, F. Dunkel, K. Schomaker, J. -M. Régis, J. Jolie, Y. H. Kim, U. Köster, G. S. Simpson, L. M. Fraile
Publikováno v:
Physical Review C. 106
Autor:
V. Guadilla, L. Le Meur, M. Fallot, J. A. Briz, M. Estienne, L. Giot, A. Porta, A. Cucoanes, T. Shiba, A.-A. Zakari-Issoufou, A. Algora, J. L. Tain, J. Agramunt, D. Jordan, M. Monserrate, A. Montaner-Pizá, E. Nácher, S. E. A. Orrigo, B. Rubio, E. Valencia, J. Äystö, T. Eronen, D. Gorelov, J. Hakala, A. Jokinen, A. Kankainen, V. Kolhinen, J. Koponen, I. Moore, H. Penttilä, I. Pohjalainen, J. Reinikainen, M. Reponen, S. Rinta-Antila, K. Rytkönen, V. Sonnenschein, A. Voss, L. M. Fraile, V. Vedia, E. Ganioğlu, W. Gelletly, M. Lebois, J. N. Wilson, T. Martinez, A. A. Sonzogni
Publikováno v:
Physical Review C. 106
Autor:
Magali Estienne, V. Guadilla, M. Fallot, A. Algora, J. L. Taín, A. Porta, L. Giot, J. A. Briz, V. M. Bui, S. Cormon, D. Jordan, L. Le Meur, S. Rice, E. Valencia, A.-A. Zakari-Issoufou, J. Agramunt, J. Äystö, A. Cucoanes, T. Eronen, L. M. Fraile, E. Ganioglu, W. Gelletly, D. Gorelov, J. Hakala, A. Jokinen, A. Kankainen, V. Kolhinen, J. Koponen, M. Lebois, T. Martinez, M. Monserrate, A. Montaner-Pizá, I. Moore, E. Nácher, S. E. A. Orrigo, H. Penttilä, S. Péru, I. Pohjalainen, J. Reinikainen, M. Reponen, S. Rinta-Antila, B. Rubio, K. Rytkönen, T. Shiba, V. Sonnenschein, A. A. Sonzogni, V. Vedia, A. Voss, J. N. Wilson
Publikováno v:
EPJ Web of Conferences. 284:02001
The accurate determination of reactor antineutrino spectra remains a very hot research topic, where new questions have emerged in recent years. Indeed, after the “reactor anomaly” – a deficit of measured antineutrinos at short baseline reactor
Autor:
J. A. Briz, M. J. G. Borge, B. Rubio, J. Agramunt, A. Algora, A. Y. Deo, M. E. Estévez Aguado, G. Farrelly, L. M. Fraile, W. Gelletly, A. Maira, E. Nácher, A. Perea, Zs. Podolyák, A. Poves, P. Sarriguren, O. Tengblad
Publikováno v:
E-Prints Complutense. Archivo Institucional de la UCM
Universidad Europea (UEM)
Digital.CSIC. Repositorio Institucional del CSIC
instname
Universidad Europea (UEM)
Digital.CSIC. Repositorio Institucional del CSIC
instname
17 pags., 13 figs., 4 tabs.
The spins and parities of low-lying states in Br72 populated in the β decay of Kr72 have been studied via conversion electron spectroscopy. The measurements were carried out at ISOLDE using a miniorange spectrometer
The spins and parities of low-lying states in Br72 populated in the β decay of Kr72 have been studied via conversion electron spectroscopy. The measurements were carried out at ISOLDE using a miniorange spectrometer
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::cb99ce09b4ae13bdba0fbd8ca5298f48
https://eprints.ucm.es/id/eprint/71015/
https://eprints.ucm.es/id/eprint/71015/
Autor:
B. Das, B. Cederwall, C. Qi, M. Górska, P. H. Regan, Ö. Aktas, H. M. Albers, A. Banerjee, M. M. R. Chishti, J. Gerl, N. Hubbard, S. Jazrawi, J. Jolie, A. K. Mistry, M. Polettini, A. Yaneva, S. Alhomaidhi, J. Zhao, T. Arici, S. Bagchi, G. Benzoni, P. Boutachkov, T. Davinson, T. Dickel, E. Haettner, O. Hall, Ch. Hornung, J. P. Hucka, P. R. John, I. Kojouharov, R. Knöbel, D. Kostyleva, N. Kuzminchuk, I. Mukha, W. R. Plass, B. S. Nara Singh, J. Vasiljević, S. Pietri, Zs. Podolyák, M. Rudigier, H. Rösch, E. Sahin, H. Schaffner, C. Scheidenberger, F. Schirru, A. Sharma, R. Shearman, Y. Tanaka, J. Vesić, H. Weick, H. J. Wollersheim, U. Ahmed, A. Algora, C. Appleton, J. Benito, A. Blazhev, A. Bracco, A. M. Bruce, M. Brunet, R. Canavan, A. Esmaylzadeh, L. M. Fraile, G. Häfner, H. Heggen, D. Kahl, V. Karayonchev, R. Kern, A. Korgul, G. Kosir, N. Kurz, R. Lozeva, M. Mikolajczuk, P. Napiralla, R. Page, C. M. Petrache, N. Pietralla, J.-M. Régis, P. Ruotsalainen, L. Sexton, V. Sanchez-Temble, M. Si, J. Vilhena, V. Werner, J. Wiederhold, W. Witt, P. J. Woods, G. Zimba
Publikováno v:
E-Prints Complutense. Archivo Institucional de la UCM
instname
instname
Direct lifetime measurements via gamma -gamma coincidences using a fast timing detector array consisting of LaBr3(Ce) scintillators has been applied to determine the lifetime of low-lying states in the semimagic (N = 50) nucleus Ru-94. The experiment
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::d5e9183dd140b76c3acfaf4c94ba3773
https://eprints.ucm.es/id/eprint/72344/1/FrailePrieto90libre+CC.pdf
https://eprints.ucm.es/id/eprint/72344/1/FrailePrieto90libre+CC.pdf
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms. 463:394-397
Gamma spectroscopy has been recast by a new generation of inorganic scintillators, mostly halide compounds, with large effective atomic number, excellent timing properties and a good energy resolution. The most prominent example is LaBr3(Ce), commerc
Autor:
S E A Orrigo, J L Tain, N Mont-Geli, A Tarifeño-Saldivia, L M Fraile, M Grieger, J Agramunt, A Algora, D Bemmerer, F Calviño, G Cortés, A DeBlas, I Dillmann, A Domínguez Bugarín, R García, E Nacher, A Tolosa
We have performed a long-term measurement of the neutron flux with the High Efficiency Neutron Spectrometry Array HENSA in the Hall A of the Canfranc Underground Laboratory. The Hall A measurement campaign lasted from October 2019 to March 2021, demo
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::acfdcc0da82ff3404c585323af435a0b
http://arxiv.org/abs/2111.09202
http://arxiv.org/abs/2111.09202
Autor:
V V Onecha, P Galve, P Ibáñez, C Freijo, F Arias-Valcayo, D Sanchez-Parcerisa, S España, L M Fraile, J M Udías
Publikováno v:
Physics in Medicine and Biology
Objective. This paper presents a new method for fast reconstruction (compatible with in-beam use) of deposited dose during proton therapy using data acquired from a PET scanner. The most innovative feature of this novel method is the production of no