Zobrazeno 1 - 7
of 7
pro vyhledávání: '"Kunihiro Eda"'
Autor:
Kunihiro Eda, Hiroaki Hata, Satoshi Kashiwazaki, Hirokazu Hirose, Motomi Shiono, Nanao Negeshi, Mitsuru Iida, Yukiyasu Sezai
Publikováno v:
Artificial Organs. 26:862-867
We contrived a surgical technique for the purpose of improving recent results. From April 1998 to June 2001, 24 patients (aged 60 to 81 years, mean age 71.0 +/- 4.8 years; 11 men, 13 women) underwent replacement of the aortic root and the ascending a
Autor:
Kin-ichi Nakata, Shinya Yagi, Nanao Negishi, Kunihiro Eda, Yoshiki Taniguchi, Yukiyasu Sezai, Yukihiko Orime, Tsutomu Hattori, Akira Saito, Michio Funahashi, Motomi Shiono
Publikováno v:
Artificial Organs. 25:728-732
The left ventricular assist device (LVAD) with centrifugal pump has two characteristics. One is a pump flow wave of the centrifugal pump, consisting of the pulsatile flow of the native heart and the nonpulsatile flow of the centrifugal pump. The othe
Autor:
Shinichiro Miyoshi, Kunihiro Eda, Yasuyuki Yamada, Fumie Saito, Yoshihiko Mochizuki, Ikuko Shibasaki, Y. Inoue, Yoshiei Shimamura
Publikováno v:
General thoracic and cardiovascular surgery. 55(10)
We assessed the feasibility and effectiveness of a novel end graft holder for coronary artery bypass grafting (CABG) and evaluated anastomotic patency and early clinical results.The end graft holder was applied to 45 consecutive patients. Operative c
Publikováno v:
The Annals of thoracic surgery. 82(2)
Background Previously, a method was reported to correct pectus excavatum in which a convex steel bar is inserted beneath the sternum. This method gained popularity, but a relatively high incidence of complications has been reported. We review our exp
Autor:
Hideaki, Mori, Yoshitaka, Okamura, Yoshihiko, Mochizuki, Hiroshi, Iida, Yasuyuki, Yamada, Kunihiro, Eda, Yuho, Inoue, Shinichiro, Miyoshi
Publikováno v:
Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia. 11(2)
Brachiocephalic artery aneurysm with concomitant coronary artery aneurysm is rare. We describe a case of a patient with a history of prosthetic graft placement following resection of an abdominal aortic aneurysm and was subsequently found to have a b
Autor:
Yukihiko Orime, Kunihiro Eda, Satoshi Kashiwazaki, Takanori Yoshino, Kin-ichi Nakata, Jun‐ichi Kinoshita, Hiroyuki Hirose, Yukiyasu Sezai, Mitsuru Iida, Takashi Koujima, Akira Saitoh, Akira Sezai, Motomi Shiono, Mitsumasa Hata, Motohiko Furuichi, Mitsuhiro Nemoto, Yoshiki Taniguchi
Publikováno v:
Artificial organs. 23(3)
We examined a major organ function during 3 h biventricular assisted circulation after acute myocardial infarction model in the pig. In left ventricular circulation, the outflow cannula was placed in the ascending aorta and an inflow cannula through
Publikováno v:
The Annals of Thoracic Surgery. 82:e27-e28
We have developed a simple technique for temporary shunt from the saphenous vein graft to the coronary artery during off-pump coronary anastomosis. The ends of a 2-mm diameter tube were inserted into the distal end of the saphenous vein graft in whic