Autor:
Kun-Xi Qian, Teng Jing
Publikováno v:
Journal of Advances in Medicine and Medical Research. :1-4
The main obstacle of artificial heart in extending its applications in clinic has been its over high price rather than technical property. The new generation of artificial heart must enable the patients to be able to afford it. The author's permanent
Autor:
Teng Jing, Kun Xi Qian
Publikováno v:
Applied Mechanics and Materials. :279-283
Streamlines in mixed-flow impeller were deduced by solving partial differential equations of continuity, motion and energy; they could be simplified to be logarithmic spiral and parabola in vertical and horizontal sections respectively. Then a mixed-
Publikováno v:
ISRN Mechanical Engineering. 2011, Special section p1-4. 4p.
Autor:
Teng Jing, Kun Xi Qian
Publikováno v:
Advanced Materials Research. :1586-1589
Permanent maglev has been since long recognized to be unstable because of Earnshaw's theory, which theoretically proved that permanent maglev can not achieve stable equilibrium in static state. How about that in dynamic state, for example, about a ro
Publikováno v:
Advanced Materials Research. 709:862-866
With the development of heart pumps, more and more commercial artificial heart have been applied to clinic use. However, most of the products produce some discomfort to human body, which coudn’t meet the physiological requirements of patients. Ther
Publikováno v:
Applied Mechanics and Materials. 150:50-56
The authors’ former works demonstrated that a passive magnetic (PM) rotator supported merely by PM bearings has a minimal speed, above which it can stabilize its equilibrium, under the function of a so-called Gyro-effect. It is unclear, however, by
Autor:
Wen Jue Wu, Wei Xing He, Jing Hua Ji, Qin Lin Wu, Fang Qun Wang, Kun Xi Qian, Lei Liu, Tian Bo Li, Wenxiang Zhao
Publikováno v:
Applied Mechanics and Materials. 140:162-166
Compared to centrifugal blood pumps, the high rotating speed of axial blood pumps lead to blood damage more easily. In order to improve blood compatibility of the axial blood pump developed by the authors, traditional method and three-dimensional str
Autor:
Kun Xi Qian
Publikováno v:
Applied Mechanics and Materials. 140:220-228
R&D of artificial heart has lasted over 50 years, now both rotary and diaphragm pumps can assist the circulation of the patients several years, after solving many technical problems. In rotary heart pumps, the basic technical problems have been the i
Autor:
Kun-Xi Qian
Publikováno v:
Health. :31-34
All existing left ventricular assist devices (LVADs) need inlet and outlet connecting con-duits and the assist pumping blood flows through the bypass circuit from left ventricle to aorta. It will result in some most likely sites of thrombosis and bri
Publikováno v:
Artificial Organs. 20:1310-1313
Because of severe hemolysis, especially on producing pulsatile flow by changing the rotating speed of the impellers, the traditional centrifugal pump was rarely used for long-term support of the failing heart. We therefore developed a motor driven pu