Publikováno v:
Physica Medica. 99:22-30
Treatment planning for ion therapy involves the conversion of computed tomography number (CTN) into a stopping-power ratio (SPR) relative to water. The purpose of this study was to create a CTN-to-SPR calibration table using a stoichiometric CTN cali
Autor:
Shintaro Tsuda, Hideharu Miura, Kosaku Habara, Takeo Nakashima, Yoshiharu Morimoto, Shuichi Ozawa, Masahiro Hayata, Hayate Kusaba, Yasushi Nagata, Hiroshige Nozaki, Mineaki Seido, Kentaro Miki, Atsushi Kawakubo, Minoru Nakao, Daisuke Kawahara, Yusuke Ochi, Kiyoshi Yamada
Publikováno v:
Medical Physics
Purpose In photon radiation therapy, computed tomography (CT) numbers are converted into values for mass density (MD) or relative electron density to water (RED). CT-MD or CT-RED calibration tables are relevant for human body dose calculation in an i
Autor:
Yoshiharu Morimoto, Katsunori Yogo, Kiyoshi Yamada, Yasushi Nagata, Kentaro Miki, Takeo Nakashima, Minoru Nakao, Hideharu Miura, Hiroshige Nozaki, Fumika Hosono, Masahiro Hayata, Yusuke Ochi, Daisuke Kawahara, Toru Yoshizaki, Shuichi Ozawa, Kosaku Habara
Publikováno v:
Journal of Applied Clinical Medical Physics
Computed tomography (CT) data are required to calculate the dose distribution in a patient’s body. Generally, there are two CT number calibration methods for commercial radiotherapy treatment planning system (RTPS), namely CT number‐relative elec
Autor:
Yasushi Nagata, Hiroshige Nozaki, Yusuke Ochi, Kosaku Habara, Minoru Nakao, Daisuke Kawahara, Takeo Nakashima, Yoshiharu Morimoto, Fumika Hosono, Shuichi Ozawa, Akito Saito, Toru Yoshizaki, Kiyoshi Yamada, Masahiro Hayata, Kentaro Miki, Katsunori Yogo
Publikováno v:
Journal of Applied Clinical Medical Physics
The accuracy of computed tomography number to electron density (CT‐ED) calibration is a key component for dose calculations in an inhomogeneous medium. In a previous work, it was shown that the tolerance levels of CT‐ED calibration became stricte
Autor:
Kosaku Habara, Naoki Hayashi, Tomohiro Shimozato, Takashi Furukawa, Ryota Kawanami, Yuichi Aoyama, Kanji Matsuura, Keisuke Yasui, Yasunori Obata
Publikováno v:
Japanese Journal of Radiological Technology. 67:1164-1173
Image-guided radiation therapy using a gold marker-based tumor tracking technique provides precise patient setup and monitoring. However, the marker consists of high-Z material, and the resulting scattered rays tend to have adverse effects on the dos