Zobrazeno 1 - 10
of 32
pro vyhledávání: '"Kongkhet Riansuwan"'
Publikováno v:
BMC Geriatrics, Vol 24, Iss 1, Pp 1-7 (2024)
Abstract Background Postoperative urinary retention (POUR) among older patients with hip fractures is common and may result in delayed ambulation, prolonged hospital stays, and urinary tract infections. Although preoperative urinary catheter indwelli
Externí odkaz:
https://doaj.org/article/2dfdd718081b4a2ca58cd9ea84ce900d
Outcomes of Proximal Femoral Locking-plate Fixation for Pathological Fractures of the Proximal Femur
Autor:
Kongkhet Riansuwan, Somkiat Jivasomboonkul, Rapin Phimolsarnti, Chandhanarat Chandhanayingyong, Apichat Asavamongkolkul
Publikováno v:
Siriraj Medical Journal, Vol 73, Iss 9, Pp 603-608 (2021)
Objective: To study the treatment outcomes of proximal femoral locking-plate fixation of pathological fractures of the proximal femur relative to clinical results, implant failure, and surgical complications. Materials and Methods: From 2007 to 2018,
Externí odkaz:
https://doaj.org/article/b48b38cb3f834520916e0c7438b4e926
Autor:
Chantas Mahaisavariya, Nomina Pradhan, Kongkhet Riansuwan, Theerawoot Tharmviboonsri, Likit Rugpolmuang, Banchong Mahaisavariya, Direk Tantigate
Publikováno v:
Siriraj Medical Journal, Vol 74, Iss 10 (2022)
Objective: A cephalomedullary nail is the treatment of choice for trochanteric fractures; however, a lag screw cutout is one of the most devastating complications. The lag screw cut-out rate was reported to be around 2.5%–8.3%. This study aimed to
Externí odkaz:
https://doaj.org/article/12b253a1fc15456d80aa80aa8df4c1c1
Publikováno v:
Siriraj Medical Journal, Vol 63, Iss 3 (2020)
A surgical technique to drain the medullary content during closed femoral nailing by using a Frazier suction tip as a vent is demonstrated. This method is simple, safe and reproducible. The medullary content can be drained outside without surrounding
Externí odkaz:
https://doaj.org/article/161a8d5fdbdf4462a48fd36e1928c88c
Publikováno v:
Case Reports in Orthopedics, Vol 2013 (2013)
This report presents a surgical technique to remove a broken cannulated nail from the femur. A Harrington rod was modified for retrograde impaction of the retained fragment. The broken implant was finally removed without complication. This particular
Externí odkaz:
https://doaj.org/article/27a2ad36072046a38d88b6ebf1c946d8
Publikováno v:
Injury. 53:323-333
The aim of this study was to assess biomechanical performance of short and long Cephalomedullary nail constructs consisting of different number of distal screw for stabilizing different levels of subtrochanteric fracture.The femur obtained from compu
Outcomes of Proximal Femoral Locking-plate Fixation for Pathological Fractures of the Proximal Femur
Autor:
Somkiat Jivasomboonkul, Rapin Phimolsarnti, Chandhanarat Chandhanayingyong, Kongkhet Riansuwan, Apichat Asavamongkolkul
Publikováno v:
Siriraj Medical Journal, Vol 73, Iss 9 (2021)
Siriraj Medical Journal, Vol 73, Iss 9, Pp 603-608 (2021)
Siriraj Medical Journal, Vol 73, Iss 9, Pp 603-608 (2021)
Background Intramedullary nailing of long bones is a common technique for management of existing or impending pathological fracture of the proximal femur. This fixation has been shown to be biomechanically superior to the locking-plate system. Howeve
Autor:
Pattarachai Kiratisin, Sarun Tulakarnwong, Kongkhet Riansuwan, Norased Nasongkla, Thanaphat Chartpitak
Publikováno v:
Journal of Drug Delivery Science and Technology. 47:223-229
Bacterial infection in Schanz pins is a major problem in orthopedic surgery. Infection is mostly caused by gram-positive bacteria including Staphylococcus aureus and Staphylococcus epidermidis. In this study, vancomycin and poly (lactic acid) were ch
Autor:
Panarin Chinavinijkul, Pattarachai Kiratisin, Kongkhet Riansuwan, Norased Nasongkla, Siriwan Srisang
Publikováno v:
Journal of Drug Delivery Science and Technology. 65:102667
In this study, variation of coating parameters was performed to determine a suitable condition for a vancomycin-coated Schanz pins in poly(lactic acid) (PLA) for prolonged antibacterial activity. Herein, the solvent used to dissolve the polymer (DCM
Publikováno v:
International Orthopaedics. 37:2443-2449
Posterior hip fracture-dislocation needs stability evaluation. A previous study in the normal acetabulum has shown that the coronal posterior acetabular arc angle (PAAA) could be used to assess an unstable posterior hip fracture. Our study was design