Zobrazeno 1 - 10
of 14
pro vyhledávání: '"Komljenović, Josipa"'
Autor:
Komljenović, Josipa, Radić, Njegomir
Publikováno v:
Acta chimica slovenica
Analytical procedures used for qualitative identification or/and quantitative determination of chemical species are based on reaction that takes place in homogeneous or heterogeneous systems. When a solid state potentiometric chemical sensor (PCS) is
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=dedup_wf_001::61c09308312ef331f31adccac1c2ee72
https://www.bib.irb.hr/236372
https://www.bib.irb.hr/236372
Autor:
Komljenović, Josipa, Radić, Njegomir
Višenamjenski protočni cjevastisenzor sa selektivnom membranom na bazi AgI, dobiven kemijskom obradom unutarnjeg dijela srebrnog valjka, umetnut je u protočni sustav u svrhu ispitivanja odziva prema koenzimu A(CoA). U svrhu optimizacije protočnog
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::a94bf653ef1d29462d0e5b2a3df8b9bd
https://www.bib.irb.hr/89810
https://www.bib.irb.hr/89810
Višenamjenski protocni cjevasti senzor sa selektivnom membranom na bazi AgI umetnut je u protocni sustav u svrhu ispitivanja elektrodnog odziva prema penicilaminu. U svrhu optimizacije protocnog sustava razlicite znacajke kao protok, volumen injekti
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::efbc03446478901b90f5ea032f2e4c99
https://www.bib.irb.hr/23321
https://www.bib.irb.hr/23321
Autor:
Komljenović, Josipa, Radić, Njegomir
A solid stet AgI-based electrode was constructed as a compact tubular sensor ; the sensing hole had an i.d. of 2.0 mm and lenght of 1.2 mm. An example of the application of the tubular electrode is given in form of the determination of cysteine (RSH)
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::504151cbb8a04a082cb0ad2eeac24236
https://www.bib.irb.hr/321584
https://www.bib.irb.hr/321584
Autor:
Radić, Njegomir, Komljenović, Josipa
The development and application of ion-selective membrane electrodes (ISME's) continues to be a rapidly growing area of analytical chemistry. However, in the standard analytical chemistry textbook little attention is given to this subject, and there
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::1e1818c1390cbc9d4ae9ec2711438bf6
https://www.bib.irb.hr/321505
https://www.bib.irb.hr/321505
Autor:
Komljenović, Josipa, Radić, Njegomir
A simple potentiometric method for the determination of N-acetylcysteine (NAC) is based on its reduction action on Fe(III) in acidic fluoride solution, pH 2. The method is described as an equilibrium method and kinetic method. The recorded potential
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::ed2c658b77679a28e4c1dcf95af06bd6
https://www.bib.irb.hr/321509
https://www.bib.irb.hr/321509
Autor:
Komljenović, Josipa, Radić, Njegomir
Potentiometric determination of thiourea (TU) in strongly acidic solution (pH=l) by using "all-solid-state" ion-selective electrode with (Ag2S 25%, AgI 25% and PTFE 50% m/m) - membrane is described. The utilized sensing electrode has been prepared in
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::3424ab77c09b059bb9c3340a32dbcf80
https://www.bib.irb.hr/321470
https://www.bib.irb.hr/321470
Autor:
Radić, Njegomir, Komljenović, Josipa
Publikováno v:
Laboratory Robotics and Automation; 1998, Vol. 10 Issue: 3 p143-149, 7p
Publikováno v:
Analytica Chimica Acta; January 1990, Vol. 231 Issue: 1 p137-141, 5p
A solid-state contact, based on the use of Ag2S, between LaF3 membrane and stainless steel disk of the multipurpose solid-state electrode body is described. LaF3 membrane in the piece of origanl epoxy barrel assembled with the solid state electrode b
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=57a035e5b1ae::0b3c4427b2d2d25b952d198c1dae79f7
https://www.bib.irb.hr/321639
https://www.bib.irb.hr/321639