Zobrazeno 1 - 10
of 13
pro vyhledávání: '"Koji Nakagiri"'
Publikováno v:
Shokubutsu Kankyo Kogaku. 27:162-170
Publikováno v:
Japanese Journal of Applied Physics. 33:1687
We show the results of computer simulations of the time scale generated by the atomic time (TA) algorithm, using data obtained from an ensemble of clocks at Communications Research Laboratory (CRL). Three accuracy evaluations were made using the labo
Publikováno v:
The Review of Laser Engineering. 12:696-701
Microwave Rabi Resonances of Cs atom are observed by using optical pumping and optical detection with a laser diode. In case of Δ F=0, π porahzed pumping light, mF=0 atoms remain in the same magnetic sublevel. This result leads to the realization o
Publikováno v:
IEEJ Transactions on Electronics, Information and Systems. 108:639-644
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 29:304-310
The Majorana effect on the hydrogen maser and the cesium (Cs) beam frequency standard is studied. In the hydrogen maser, the Majorana transition is used to the state selection successfully to eliminate the atoms in the [F = 1, mF = 1] state. As the r
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. 27:343-348
A laboratory type cesium beam standard is being constructed for experimental use as a working standard at the RRL of Japan. Ihe structural design and experimental results on the phase adjustment of Ramsey cavity, the beam optics employing hexapole ma
Publikováno v:
IEEE Transactions on Instrumentation and Measurement. :617-619
In order to set the C field, we use both field-dependent transitions, (F = 4, m F = + 1) → (F = 3, m F = ±1), to control the fluctuation and to compensate the effect of C field uniformity. The side-lobes of these transitions pull the center freque
Publikováno v:
Frequency Standards and Metrology ISBN: 9783642745034
Initially, beam tube experiments adopted an H-plane-bend Ramsey cavity using an E-plane feed and a solenoid coil to make a uniform C-field [1], [2]. This system is similar to the Cs 1 and 2 atomic clocks at PTB. Thereafter a conventional type E-bend
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::7b09a3c67cce574bdf9e80b6cbba7898
https://doi.org/10.1007/978-3-642-74501-0_67
https://doi.org/10.1007/978-3-642-74501-0_67
Publikováno v:
Japanese Journal of Applied Physics. 27:2383
A simulation of a cesium-beam primary frequency standard, using a beam-trajectory method, is carried out. In the calculations, the following assumptions are made: 1) the beam collimator has a finite area instead of a point source, 2) the effective di
Publikováno v:
Frequency Standards & Metrology - Proceedings of the Fifth Symposium; 1996, p417-418, 2p