Publikováno v:
日本建築学会環境系論文集. 74(640):721-728
In the work reported here, we investigated the items listed below to identify factors that affect the ICT machine air intake temperature, focusing on the effects of machine cooling characteristics on air conditioning efficiency. 1)We created a machin
Publikováno v:
大会学術講演梗概集. D-2, 環境工学II, 熱, 湿気, 温熱感, 自然エネルギー, 気流・換気・排煙, 数値流体, 空気清浄, 暖冷房・空調, 熱源設備, 設備応用. 2007:1105-1108
Publikováno v:
日本建築学会技術報告集 : journal of architecture and building science. 15:151-154
This paper describes about the effect of layout plans for outdoor condensing units on the operating efficiency of air conditioners. In the case of limited space for outdoor condensing units, it was found that an optimal value exists for the placement
Publikováno v:
日本建築学会計画系論文集. 543:41-47
The data processing equipment that is installed in computer rooms generates a large amount of heat, which is unevenly distributed in the room and may result in undesirably high local temperatures at places within the room. When the air-conditioning c
Publikováno v:
日本建築学会計画系論文集. 541:31-36
The purpose of this report is to develop a scheme for optimal placement of outdoor condensing unit. With this purpose, we examine the relationship between rise in suction temperature and the placement of outdoor condensing unit in multi-level install
Publikováno v:
日本建築学会計画系論文集. 522:67-73
The objective of this research is to develop a scheme for optimal placement of outdoor condensing unit. To this end, we examine the relationship between rise in suction temperature and the placement of outdoor condensing unit in multi-level installat
Publikováno v:
日本建築学会技術報告集 : journal of architecture and building science. 5:183-188
The purpose of this study is to quantify the indoor air quality of multi-family houses and to obtain the basic data for the estimation of air quality by using the volatilizing rate of each part of the finishing material. This research aims to analyze
Publikováno v:
日本建築学会計画系論文集. 494:29-36
A new energy-efficient air conditioning system in proposed for a computer room with high heat generating equipment where forced air cooling air volume is prescribed. In the proposed air conditioning system, conditioned primary air from the AHU is red
Publikováno v:
日本建築学会技術報告集 : journal of architecture and building science. 4:65-70
Installing outdoor units of air-cooled, separated type packaged air-conditioners in a concentrated way can reduce their cooling capacity and overall efficiency due to a temperature rise in the cooling air caused by a short circuiting of the exhaust a
Publikováno v:
大会学術講演梗概集. D-2, 環境工学II, 熱, 湿気, 温熱感, 自然エネルギー, 気流・換気・排煙, 数値流体, 空気清浄, 暖冷房・空調, 熱源設備, 設備応用. 2006:1257-1258