Zobrazeno 1 - 10
of 17
pro vyhledávání: '"Kenji Tochigi"'
Autor:
Yusuke Aramomi, You Yin, Hirokazu Koyabu, Kenji Tochigi, Hayato Sone, Sumio Hosaka, Eiji Sato
Publikováno v:
Key Engineering Materials. 459:129-133
We have prototyped illumination-collection mode scanning near-field optical microscopy (SNOM) and near-field Raman spectroscopy (NFRS) with gold inner-covered aperture-less pyramidal probe in order to study the possibility to detect optical images, a
Publikováno v:
TEION KOGAKU (Journal of Cryogenics and Superconductivity Society of Japan). 29:223-228
Specific heats of polyvinylformal, which is insulator for superconducting wires, and carbon for thermometers are measured in the temperature range from 14K to 248K for the former and ranges from 14K to 201K and from 243K to 274K for the latter by an
Publikováno v:
The Journal of Chemical Thermodynamics. 25:699-709
An adiabatic calorimeter was constructed for samples of low mass. By placing its thermometer on the adiabatic shield surrounded the calorimetric cell, the internal volume of the cell could be reduced to 0.1 cm3. The molar heat capacities Cp, m of a s
Publikováno v:
BUNSEKI KAGAKU. 42:7-12
キャピラリー電気泳動にてタンパク質を分析する場合,分離管に用いるキャピラリーの内壁にタンパク質が吸着し,分離能,測定の再現性が悪くなるという問題がある.本報では,内壁に固定
Publikováno v:
BUNSEKI KAGAKU. 41:485-489
キャピラリー電気泳動にてタンパク質を分析する場合,分離管に用いるキャピラリーの内壁にタンパク質が吸着し,分離能,測定の再現性が悪くなるという問題がある.本報では,キャピラリ
Publikováno v:
BUNSEKI KAGAKU. 40:395-400
HPLCによるグリコヘモグロビン,特に安定型A1c(s-A1c)の高速分析法について検討した.メタクリレート系ゲルにカルボキシメチル基を導入した5μm充てん剤(市販品レベル)と3.5μm充てん剤を試作
Publikováno v:
BUNSEKI KAGAKU. 40:907-912
グリコヘモグロビンの高速分析を目的とし,グリコヘモグロビンの分離に好適な充てん剤の物性について調べた.粒径3.7~3.9μm,交換容量0.26~0.29meq/gとほぼ一定で,細孔径の異なるポリメタ
Publikováno v:
Journal of the Ceramic Society of Japan. 99:461-466
Porous insulation films of alumina used in color picture tube heaters for high definition displays have been made by electrophoretic deposition (electrodeposition) process. In this process, the formation of gels on electrodes and the electrophoresis
Publikováno v:
Applied Spectroscopy. 46:156-158
A polarization-modulation technique has been combined with Fourier transform infrared (FT-IR) spectrometry to eliminate the large background radiation which interferes with the infrared emission from thin organic films on metal surfaces. A step scan
Autor:
Kenji Tochigi, Anthony F. Garito, Akira Yamada, Yasushi Iwakabe, Masahiko Hara, Akio Mukoh, K. Kondo, Hiroyuki Sasabe
Publikováno v:
Japanese Journal of Applied Physics. 30:2542
The anchoring structures of a homologous series of liquid crystals, n-alkylcyanobiphenyls (mCBs: m=7-12), on molybdenum disulfide (MoS2) are directly observed by scanning tunneling microscopy (STM) in order to analyze the alignment mechanism of liqui