Zobrazeno 1 - 10
of 59
pro vyhledávání: '"Kenan Unlu"'
Publikováno v:
Journal of Radioanalytical and Nuclear Chemistry. 322:1563-1570
Regulatory monitoring of oil and gas development requires the accurate multi-elemental analysis of wellbore samples on a regular basis. In this study, an unconventional method, comparative neutron activation analysis (comparative NAA), was applied fo
Publikováno v:
Journal of Radioanalytical and Nuclear Chemistry. 322:1529-1535
Fifteen tile samples from archaeological digs in central Italy were analyzed for trace element content using comparative neutron activation analysis. To accommodate the simultaneous irradiation of a large number of samples and standard reference mate
Publikováno v:
EPJ Web of Conferences, Vol 247, p 14002 (2021)
In 2010, the Department of Nuclear Engineering at Khalifa University of Science and Technology (NUCE) established the MSc degree in Nuclear Engineering. This program was established to support the United Arab Emirates (UAE) emerging civil nuclear ene
Publikováno v:
Artificial Intelligence and Applied Mathematics in Engineering Problems ISBN: 9783030361778
In this study making of 3D bionic hand for people who was born without hand or who has lost their hand after accidents. Researches are carried out before making the 3D design of bionic hand, upper extremity drawings and the situations which should be
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d8096d0bdd8658a68029d8addc5d4c33
https://doi.org/10.1007/978-3-030-36178-5_62
https://doi.org/10.1007/978-3-030-36178-5_62
Autor:
Aleksey E. Bolotnikov, R. Gul, Giuseppe S. Camarda, Emerson Vernon, Anwar Hossain, Kenan Unlu, L. Ocampo Giraldo, Ge Yang, G. De Geronimo, Jack Fried, Ralph B. James, Deidra Hodges
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 884:136-139
We evaluated the sub-pixel position resolution achievable in large-volume CdZnTe pixelated detectors with conventional pixel patterns and for several different pixel sizes: 2.8 mm, 1.72 mm, 1.4 mm and 0.8 mm. Achieving position resolution below the p
Autor:
G. De Geronimo, Kenan Unlu, M. Petryk, A. McGilloway, L. Ocampo Giraldo, Ge Yang, Emerson Vernon, V. Vidal, Giuseppe S. Camarda, Aleksey E. Bolotnikov, Anwar Hossain, Ralph B. James, Jack Fried, Diedra R. Hodges, S. Cheng
Publikováno v:
IEEE Transactions on Nuclear Science. 64:2698-2705
Position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors offer a unique capability for correcting the response nonuniformities caused by crystal defects. This allowed us to achieve high energy resolution, while using typical-grade commerci
Autor:
Ge Yang, L. Ocampo Giraldo, M. Petryk, Kenan Unlu, V. Vidal, G. De Geronimo, Giuseppe S. Camarda, Anwar Hossain, Jack Fried, S. Cheng, Ralph B. James, Aleksey E. Bolotnikov, Emerson Vernon, Deidra Hodges, A. McGilloway
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 867:7-14
We evaluated the X-Y position resolution achievable in 3D pixelated detectors by processing the signal waveforms readout from neighboring pixels. In these measurements we used a focused light beam, down to 10 μ m, generated by a ∼1 mW pulsed laser
Publikováno v:
Nuclear Technology. 197:201-208
This paper describes the novel implementation of a vacuum-micro-electronic (VME) device configured as a wireless transmitter capable of transmitting, within a nuclear radiation environment, a radio-frequency signal proportional to a voltage input. Th
Publikováno v:
EPJ Web of Conferences, Vol 253, p 04012 (2021)
Preliminary results of characterization experiments for the New Neutron Imaging Facility (NIF) that is being developed at the Penn State Breazeale Nuclear reactor are presented in the following sections. The methodology of neutron beam characterizati