Zobrazeno 1 - 10
of 22
pro vyhledávání: '"Kelly Swinney"'
Autor:
Stephanie Krogmeier, Justin Pritchard, Eleni Dokou, Sue Miles, Gregory Connelly, Joseph Medendorp, Michael Bourland, Kelly Swinney
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::19f4f83ea405a82ced0d4198584199b2
https://doi.org/10.1016/b978-0-12-813479-5.00003-3
https://doi.org/10.1016/b978-0-12-813479-5.00003-3
Autor:
Michael Bourland, Gregory Connelly, Alberto M. Cuitiño, Eleni Dokou, M. Sebastian Escotet-Espinoza, Mauricio Futran, Marcial Gonzalez, Douglas B. Hausner, Marianthi Ierapetritou, Lalith Kotamarthy, Stephanie Krogmeier, Hwahsiung P. Lee, Tianyi Li, Joseph Medendorp, Nirupaplava Metta, Sue Miles, Christine M.V. Moore, Shashank Venkat Muddu, Fernando J. Muzzio, Oliver Nohynek, Sarang Oka, Savitha Panikar, Justin Pritchard, Rohit Ramachandran, William Randolph, Sonia M. Razavi, Eric Sánchez Rolón, Rodolfo J. Romañach, Andrés D. Román-Ospino, James V. Scicolone, Ravendra Singh, Stephen Sirabian, Kelly Swinney, Zilong Wang, Yifan Wang, Bereket Yohannes
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::d0ae96d88f55876dc09da474d03b1438
https://doi.org/10.1016/b978-0-12-813479-5.01002-8
https://doi.org/10.1016/b978-0-12-813479-5.01002-8
Publikováno v:
Journal of the American Chemical Society. 126:16659-16664
Quantification of protein-protein and ligand-substrate interactions is central to understanding basic cellular function and for evaluating therapeutics. To mimic biological conditions, such studies are best executed without modifying the proteins or
Publikováno v:
ELECTROPHORESIS. 23:809-812
EL 4823 Polarimetry has long served as reliable noninvasive method for molecular structure and concentration investigations. It has been often used in pharmaceutical industry for purity control of certain biological substances, in chemical industry f
Autor:
Darryl J. Bornhop, Kelly Swinney
Publikováno v:
ELECTROPHORESIS. 23:613-620
We present the use of a novel, picoliter volume interferometer to measure, for the first time, the extent of Joule heating in chip-scale capillary electrophoresis (CE). The simple optical configuration for the on-chip interferometric backscatter dete
Publikováno v:
Applied Spectroscopy. 56:134-138
Autor:
Darryl J. Bornhop, Kelly Swinney
Publikováno v:
ELECTROPHORESIS. 22:2032-2036
Using the on-chip refractive index (RI) detector based on backscatter interferometry, sensitive, small volume, noninvasive thermometry can be performed. The current optical configuration for the on-chip interferometric backscatter detector (OCIBD) is
Autor:
Darryl J. Bornhop, Kelly Swinney
Publikováno v:
Applied Spectroscopy. 54:1485-1489
A laser-based capillary polarimetric detector (CPD) has been configured to allow for the analysis of optically active molecules at physiological temperatures and within a 40 nL sample volume. In the CPD, interference fringes contained within a 360°
Publikováno v:
Review of Scientific Instruments. 71:2684-2692
A microinterferometric backscatter detector (MIBD) has been developed to perform subnanoliter volume refractive index measurements using a simple, folded optical train based on the interaction of a laser beam and a fused silica capillary tube. Positi
Autor:
Kelly Swinney, Darryl J. Bornhop
Publikováno v:
Electrophoresis. 21:1239-1250
A review of the four major, on-line, capillary electrophoresis (CE) detection modalities is presented. It is shown that each detection method, fluorescence, absorbance (conventional and nonconventional), electrochemical and refractive index, have dis