Kazumi Mizuguchi, Kozo Naito, Julie Glueck, Yasuhisa Ohara, Setsuo Takatani, Yukihiko Nosé, Kenzo Makinouchi, George P. Noon, George Damm, Yukihiko Orime, Ichiro Sakuma, Kimitaka Tasai
Publikováno v:
Artificial Organs. 17:599-604
A seal-less centrifugal pump aiming for long-term circulatory support has been developed. In this model, shaft seals that cause thrombus formation and blood leakage were eliminated. A brushless direct current motor was incorporated as a driving unit,
Autor:
Kazumi Mizuguchi, Richard J. Bozeman, Setsuo Takatani, Michael E. DeBakey, George Damm, Yukihiko Nosé, George P. Noon, G. Aber, Paul A. Svejkovsky, J. Akkerman
Publikováno v:
Artificial Organs. 17:609-613
A cooperative effort between Baylor College of Medicine and NASA/Johnson Space Center is under way to develop an implantable axial flow left ventricular assist device (LVAD). The pump is intended as an assist device for either pulmonary or systemic c
Autor:
Toru Masuzawa, Kazumi Mizuguchi, Akio Kishida, Takashi Horiuchi, Takafumi Okoshi, Motonobu Nishimura, Hiroshi Watanabe, Takahiro Shinzato, Eisuke Tatsumi, Yasuko Tomizawa, Yoshiki Sawa
Publikováno v:
Journal of Artificial Organs. 9:1-7
Autor:
Akira Yoshioka, Kazumi Mizuguchi, Takashi Ueda, Mitsuru Nakajima, T Kawata, Shigeki Taniguchi
Publikováno v:
The Annals of Thoracic Surgery. 75:1429-1433
Background There are few reports that demonstrate the chronologic changes in the functional integrity of the internal thoracic artery (ITA) wall after skeletonization. We investigated the impact of skeletonization on ITA wall integrity by immunohisto
A 66-year-old man was referred for treatment of critical limb ischemia arising with multiple organ dysfunction due to acute pneumonia. Angiographic examinations demonstrated total obstruction of the bilateral external iliac arteries and the bilateral
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::152a861398bf8bfb7a5ab175fad1bfe7
https://europepmc.org/articles/PMC4072867/
https://europepmc.org/articles/PMC4072867/
Autor:
Yoichi Kameda, Hiroaki Nishioka, T Kawata, Shigeki Taniguchi, Kazumi Mizuguchi, Shuichi Kobayashi, Soichiro Kitamura, Shuji Sakaguchi, Tsuyoshi Tsuji
Publikováno v:
The Japanese Journal of Thoracic and Cardiovascular Surgery. 47:388-393
Objectives: We have investigated the effects and outcome from grafting the right internal thoracic artery to the left anterior descending artery in coronary artery bypass grafting.Methods: We analyzed the findings in 185 patients who underwent corona
Comparative Rest and Exercise Hemodynamics of Allograft and Prosthetic Valves in the Aortic Position
Autor:
Yoichi Kameda, Hiroaki Nishioka, Junichi Hasegawa, Soichiro Kitamura, Kazuo Niwaya, Shigeki Taniguchi, Kazumi Mizuguchi, T Kawata
Publikováno v:
The Annals of Thoracic Surgery. 64:1753-1756
Background . Allograft aortic valve replacement has gained widespread acceptance. However, there is little information about in vivo allograft valve function at rest and during exercise. Methods . Cardiac catheterization was performed to measure hemo
Autor:
Shigeki Taniguchi, Soichiro Kitamura, Yoshihiko Hirao, Kazumi Mizuguchi, Kobayashi S, Shigeo Nagasaka, Tetsuji Kawata
Publikováno v:
Heart and Vessels. 12:199-202
During left nephrectomy in a 35-year-old woman with a left renal cell carcinoma extending into the inferior vena cava (IVC) and right atrium, cardiac arrest occurred. Immediate transesophageal echocardiography demonstrated that the event was caused b
Autor:
Kazumi Mizuguchi, George Damm, Robert Benkowsky, Greg Aber, Jim Bacak, Paul Svjkovsky, Julie Glueck, Setsuo Takatani, Yukihiko Nosé, George P. Noon, Michael E. DeBakey
Publikováno v:
Artificial Organs. 19:653-659
A collaborative effort between Baylor College of Medicine and NASA/Johnson Space Center is underway to develop an axial flow ventricular assist device (VAD). We evaluated inducer/impeller component designs in a series of in vitro hemolysis tests. As
Autor:
Yasuhisa Ohara, Paul A. Svejkovsky, Yukihiko Nosé, Kimitaka Tasai, Kozo Naito, George Damm, Greg S. Aber, Kazumi Mizuguchi, Richard J. Bozeman, Jim W. Bacak, Setsuo Takatani, Kenzo Makinouchi, Michael E. DeBakey, George P. Noon, Yukihiko Orime
Publikováno v:
Artificial Organs. 18:650-656
The effect of hematocrit (Ht) on in vitro hemolysis test results (i.e., index of hemolysis) was evaluated using a Baylor/NASA prototype axial flow pump. Red blood cell suspensions of six different Ht (5, 10, 15, 20, 30, 40%; n = 30) were prepared and