Autor:
Neil Voskoboynikov, Jeffrey A. LaRose, Michael C. Brown, Nathalie J. Nunez, Carlos Reyes, Daniel Tamez, Katherine Chorpenning, Daniel Burkhoff
Publikováno v:
ASAIO Journal. 62:15-19
Controller algorithms are an important feature for assessment of ventricular assist device performance. Flow estimation is one algorithm implemented in the HeartWare continuous-flow ventricular assist device pump system. This parameter estimates flow
Autor:
Daniel Tamez, Michael Ashenuga, Katherine Chorpenning, Charles R. Shambaugh, M. Ertan Taskin, Anne E. Dierlam, Jeffrey A. LaRose, Carlos Reyes, Anson Cheung
Publikováno v:
Innovations (Philadelphia, Pa.)
Objective Ventricular assist device (VAD) miniaturization is one design trend that may result in less-invasive implantation techniques and more versatility with patient selection. The MVAD System is a miniature, continuous-flow device implanted in th
Autor:
Guruprasad A. Giridharan, Leslie C. Sherwood, Gretel Monreal, Kevin G. Soucy, Steven C. Koenig, Mark S. Slaughter, Charles R. Shambaugh, Katherine Chorpenning, Daniel Tamez, Jeffrey A. LaRose, Michael A. Sobieski
Publikováno v:
ASAIO Journal. 60:170-177
Implantation of ventricular assist devices (VADs) for the treatment of end-stage heart failure (HF) falls decidedly short of clinical demand, which exceeds 100,000 HF patients per year. Ventricular assist device implantation often requires major surg
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992). 60(5)
As a result of stagnant heart transplantation rates, ventricular assist devices (VADs) have become a widely accepted therapy for the treatment of advanced-stage heart failure. Long-term reliability of VADs will become increasingly vital as the popula
Autor:
Maxine Qun Liu, Matthew W. Miller, Katherine Chorpenning, Katherine Bonugli, Mark Lenox, D Tamez, Egemen Tuzun, Theresa W. Fossum
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992). 60(1)
The effects of the continuous-flow output on renal and intestinal microcirculation have not been extensively studied. To address this, the Heartware HVAD pump loaded with continuous and intermittent reduced speed (IRS) modes was implanted in four she
Autor:
Edwin C. McGee, Eugene Breznock, Katherine Chorpenning, Jeffrey A. LaRose, Daniel Tamez, Michael C. Brown
Publikováno v:
The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation. 33(4)
Objective The current design trend for left ventricular assist devices (LVADs) is miniaturization, which aims to increase the treatable patient population and enable new treatment indications by reducing surgical trauma and the complications associat
Publikováno v:
The Journal of Heart and Lung Transplantation. 33:S231-S232
s S231 fibrillation. Patients reported implant related pain (83%), swelling (5%), and bruising (22%). There were also 3 catheter dislocations in 2 patients. Conclusion: The procedure for implanting and tunneling a fully implantable system is easily p