Mohammad Alasti, Colin Machado, Karthikeyan Rangasamy, Logan Bittinger, Stewart Healy, Emily Kotschet, David Adam, Jeff Alison
Publikováno v:
Journal of Arrhythmia, Vol 34, Iss 5, Pp 485-492 (2018)
Abstract Pacemakers can be directly involved in initiating or sustaining different forms of arrhythmia. These can cause symptoms such as dyspnea, palpitations, and decompensated heart failure. Early detection of these arrhythmias and optimal pacemake
Externí odkaz:
https://doaj.org/article/db5dd7f372d74abeaa09165f313feb77
Autor:
Mohammad Alasti, MD, Kunal Verma, MBBS, FRACP, Karthikeyan Rangasamy, MBBS, FRACP, Stewart Healy, MBBS, FRACP, Emily Kotschet, MBBS, FRACP
Publikováno v:
Indian Pacing and Electrophysiology Journal, Vol 17, Iss 2, Pp 50-53 (2017)
We discuss a 46-year-old man with history of hypertension and inferior wall myocardial infarction and mild left ventricular dysfunction who presented with aborted sudden cardiac death due to episodes of ventricular tachyarrhythmia detected by a Revea
Externí odkaz:
https://doaj.org/article/4d5bdd7b1afc4bfe8cb1a61a6eee490e
Publikováno v:
Journal of Arrhythmia, Vol 33, Iss 6, Pp 652-654 (2017)
Here, we discuss the case of a man with a history of ischemic cardiomyopathy and cardiac resynchronization therapy defibrillator implantation, who presented to emergency department with decompensated heart failure due to the loss of resynchronization
Externí odkaz:
https://doaj.org/article/810c7b6c8c084da79ae7909756531ee4
Autor:
Divya, Karutha Pandian, Karthikeyan, Rangasamy, Sinduja, Bharathi, Anancia Grace, Arockiajawahar, John, S. Abraham, Hahn, Jong Hoon, Dharuman, Venkataraman
Publikováno v:
In Biosensors and Bioelectronics 15 May 2019 133:48-54
Publikováno v:
In Biosensors and Bioelectronics 15 August 2017 94:30-38
Autor:
Klein Christoph, Florian Blaschke, Uwe Reichert, Tony Kull, Frank R. Heinzel, Burkert Pieske, Felix Hohendanner, Karthikeyan Rangasamy, Abdul Shokor Parwani, Thomas Beiert, Philip Franke, Rafal Supryn, Andreas Kucher, Leif-Hendrik Boldt, Philipp Lacour
Background Implantable cardioverter defibrillators use low-voltage shock impedance measurements to monitor the lead integrity. However, previous case reports suggest that low-voltage shock impedance measurements may fail to detect insulation breaches
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::c6e6f1227826871282ab540967647358
Publikováno v:
Indian Pacing and Electrophysiology Journal, Vol 17, Iss 2, Pp 50-53 (2017)
Indian Pacing and Electrophysiology Journal
Indian Pacing and Electrophysiology Journal
We discuss a 46-year-old man with history of hypertension and inferior wall myocardial infarction and mild left ventricular dysfunction who presented with aborted sudden cardiac death due to episodes of ventricular tachyarrhythmia detected by a Revea
Publikováno v:
Journal of Arrhythmia, Vol 33, Iss 6, Pp 652-654 (2017)
Journal of Arrhythmia
Journal of Arrhythmia
Here, we discuss the case of a man with a history of ischemic cardiomyopathy and cardiac resynchronization therapy defibrillator implantation, who presented to emergency department with decompensated heart failure due to the loss of resynchronization
Autor:
Karthikeyan Rangasamy, Sarah Zaman, Jeff Alison, E. Kotschet, Hashrul Rashid, Robert Gooley, Mohammad Alasti, David Adam
Publikováno v:
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac AngiographyInterventions. 92(4)
Objectives To determine permanent pacemaker (PPM) dependency following transcatheter aortic valve replacement (TAVR) with the Lotus™ valve system (Boston Scientific), and the impact of PPM implantation on long-term morbidity and mortality. Backgrou