Zobrazeno 1 - 10
of 45
pro vyhledávání: '"Karl Zeitelhack"'
Autor:
L. Lopes, P.-O. Svensson, A. Blanco, S. Schmidt, A. Morozov, Richard Hall-Wilton, Karl Zeitelhack, L. Robinson, P. Fonte, Carina Höglund, L.M.S. Margato
Resistive plate chambers (RPC) lined with $^{10}B_{4}$C neutron converters is a promising cost effective technology for position-sensitive thermal neutron detection capable to outperform $^{3}$He-based detectors in terms of spatial resolution and tim
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::45d2adb64651a9231d33c8cf47fb7fbb
http://arxiv.org/abs/2002.00991
http://arxiv.org/abs/2002.00991
Autor:
V. N. Solovov, Karl Zeitelhack, A. Morozov, K. Roemer, A. Blanco, Richard Hall-Wilton, L. Robinson, J. Saraiva, Th. Wilpert, Carina Höglund, L.M.S. Margato
Publikováno v:
Journal of Instrumentation. 16:P08032
Multilayer position-sensitive 10B-RPC thermal neutron detectors offer an attractive combination of sub-millimeter spatial resolution and high (>50%) detection efficiency. Here we describe a new position reconstruction method based on a statistical ap
Autor:
P. Fonte, L. Lopes, Karl Zeitelhack, K. Roemer, Daniel Stach, L. Naumann, Th. Wilpert, A. Morozov, J. Saraiva, Carina Höglund, Richard Hall-Wilton, A. Blanco, Per Svensson, L.M.S. Margato, L. Robinson
Publikováno v:
Journal of Instrumentation 16(2021), P07009
We present experimental results on the counting rate measurements for several single-gap $^{10}$B lined resistive plate chambers ($^{10}$B-RPCs) with anodes made from standard float glass, low resistivity glass and ceramic. The measurements were perf
Autor:
Heinz Günter Brokmeier, Wei Min Gan, Jens Krueger, Karl F. Braun, Enrico Faulhaber, Michael Hofmann, I. Defendi, Christian Randau, Karl Zeitelhack, Joana Rebelo-Kornmeier
Publikováno v:
Rebelo Kornmeier, J.; Hofmann, M.; Gan, W.M.; Randau, C.; Braun, K.; Zeitelhack, K.; Defendi, I.; Krueger, J.; Faulhaber, E.; Brokmeier, H.-G.: New Developments of the Materials Science Diffractometer STRESS-SPEC. In: Holden T.; Ungar T.; Buslaps T.; Pirling T. (eds.): Materials Science Forum. Vol. 905 Zürich-Stafa: Trans Tech Publications, 2017. 151-156. (DOI: /10.4028/www.scientific.net/MSF.905.151) (ISBN: 978-303835635-6)
The high flux neutron diffractometer STRESSSPEC at FRM II, Garching Germany, offers a flexible instrument setup suitable for fast and surface residual strain measurements. Likewise bulk, local or gradient texture analyses are feasible. Here improveme
Autor:
Richard Hall-Wilton, Enrico Perelli Cippo, Giovanni Grosso, Marica Rebai, Marco Tardocchi, Karl Zeitelhack, Nigel J. Rhodes, Giuseppe Gorini, Gabriele Croci, I. Defendi, L. Robinson, D. Raspino, Erik Schooneveld, Carina Höglund, F. Murtas, Andrea Muraro
Publikováno v:
The European physical journal plus 134 (2019): 166-1–166-8. doi:10.1140/epjp/i2019-12522-5
info:cnr-pdr/source/autori:Croci, Gabriele; Muraro, Andrea; Cippo, Enrico Perelli; Grosso, Giovanni; Hoglund, Carina; Hall-Wilton, Richard; Murtas, Fabrizio; Raspino, Davide; Robinson, Linda; Rhodes, Nigel; Rebai, Marica; Schooneveld, Erik; Defendi, Ilario; Zeitelhack, Karl; Tardocchi, Marco; Gorini, Giuseppe/titolo:I-BAND-GEM: a new way for improving BAND-GEM efficiency to thermal and cold neutrons/doi:10.1140%2Fepjp%2Fi2019-12522-5/rivista:The European physical journal plus/anno:2019/pagina_da:166-1/pagina_a:166-8/intervallo_pagine:166-1–166-8/volume:134
info:cnr-pdr/source/autori:Croci, Gabriele; Muraro, Andrea; Cippo, Enrico Perelli; Grosso, Giovanni; Hoglund, Carina; Hall-Wilton, Richard; Murtas, Fabrizio; Raspino, Davide; Robinson, Linda; Rhodes, Nigel; Rebai, Marica; Schooneveld, Erik; Defendi, Ilario; Zeitelhack, Karl; Tardocchi, Marco; Gorini, Giuseppe/titolo:I-BAND-GEM: a new way for improving BAND-GEM efficiency to thermal and cold neutrons/doi:10.1140%2Fepjp%2Fi2019-12522-5/rivista:The European physical journal plus/anno:2019/pagina_da:166-1/pagina_a:166-8/intervallo_pagine:166-1–166-8/volume:134
The BAND-GEM detector represents one of the novel thermal neutron detection devices that have been developed in order to fulfil the needs of high intensity neutron sources that, like ESS (the European Spallation Source), will start operation in the n
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::335a97945a4d91f96937fe9b1a1f602d
http://www.cnr.it/prodotto/i/444180
http://www.cnr.it/prodotto/i/444180
Autor:
Karl Zeitelhack, Susann Schmidt, L. Robinson, Carina Höglund, L.M.S. Margato, A. Blanco, A. Morozov, Bruno Guerard, Richard Hall-Wilton, A. Mangiarotti, P. Fonte, F.A.F. Fraga
Publikováno v:
Journal of Instrumentation
Journal of Instrumentation, IOP Publishing, 2019, 14 (01), pp.P01017. ⟨10.1088/1748-0221/14/01/P01017⟩
JINST
JINST, 2019, 14 (01), pp.P01017. ⟨10.1088/1748-0221/14/01/P01017⟩
Journal of Instrumentation, IOP Publishing, 2019, 14 (01), pp.P01017. ⟨10.1088/1748-0221/14/01/P01017⟩
JINST
JINST, 2019, 14 (01), pp.P01017. ⟨10.1088/1748-0221/14/01/P01017⟩
The results of an experimental feasibility study of a position sensitive thermal neutron detector based on a resistive plate chamber (RPC) are presented. The detector prototype features a thin-gap (0.35 mm) hybrid RPC with an aluminium cathode lined
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::600f400f6c1e4c4021692db054d81cd1
http://arxiv.org/abs/1809.09677
http://arxiv.org/abs/1809.09677
Autor:
D. Raspino, L. Robinson, Erik Schooneveld, Karl Zeitelhack, Gabriele Croci, Carina Höglund, Marco Tardocchi, I. Defendi, Nigel J. Rhodes, Giuseppe Gorini, Enrico Perelli Cippo, Richard Hall-Wilton, Giorgia Albani, Giovanni Grosso, Susan Schmidt, Andrea Muraro, Giuliano Angella
Publikováno v:
Europhysics letters (Online) 123 (2018): 52001-1–52002-7. doi:10.1209/0295-5075/123/52001
info:cnr-pdr/source/autori:Croci G.; Muraro A.; Cippo E.P.; Tardocchi M.; Grosso G.; Albani G.; Angella G.; Defendi I.; Hall-Wilton R.; Hoglund C.; Raspino D.; Rhodes N.; Robinson L.; Schmidt S.; Schooneveld E.; Zeitelhack K.; Gorini G./titolo:A high-efficiency thermal neutron detector based on thin 3D 10B4C converters for high-rate applications/doi:10.1209%2F0295-5075%2F123%2F52001/rivista:Europhysics letters (Online)/anno:2018/pagina_da:52001-1/pagina_a:52002-7/intervallo_pagine:52001-1–52002-7/volume:123
info:cnr-pdr/source/autori:Croci G.; Muraro A.; Cippo E.P.; Tardocchi M.; Grosso G.; Albani G.; Angella G.; Defendi I.; Hall-Wilton R.; Hoglund C.; Raspino D.; Rhodes N.; Robinson L.; Schmidt S.; Schooneveld E.; Zeitelhack K.; Gorini G./titolo:A high-efficiency thermal neutron detector based on thin 3D 10B4C converters for high-rate applications/doi:10.1209%2F0295-5075%2F123%2F52001/rivista:Europhysics letters (Online)/anno:2018/pagina_da:52001-1/pagina_a:52002-7/intervallo_pagine:52001-1–52002-7/volume:123
A new position-sensitive thermal neutron detector based on boron-coated converters has been developed as an alternative to today's standard 3 He-based technology for application to thermal neutron scattering. The key element of the development is a n
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::b51789d812e6e4e8ce3026b0246d7cf6
http://hdl.handle.net/10281/207835
http://hdl.handle.net/10281/207835
Autor:
Karl Zeitelhack, Carina Höglund, Jens Birch, I. Stefanescu, I. Defendi, Richard Hall-Wilton, Y. Abdullahi, D. Seiler, Lars Hultman
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 727:109-125
We present a novel design for a macrostructured cathode that can be coated with a thin layer of the B-10 solid converter and mounted to replace the Boron-lined flat parallel plates of a proportional counter used for slow neutron detection. The propos
Autor:
Karl Zeitelhack
Publikováno v:
Neutron News. 23:10-13
Since helium-3 became easily available in large quantities in the 1980s it has become the dominant converter material used in detectors for neutron scattering applications due to its outstanding pe...
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 586:90-94
The neutron spin-echo instrument, J-NSE, that has been moved from the ELLA guide hall at the FRJ-2 in Julich to the guide hall of the new FRM II reactor, needs an intense beam of polarized neutrons. Polarization of the short wavelengths is achieved i