Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Kari Riski"'
Publikováno v:
NCSLI Measure. 9:56-60
We are developing a novel gravimetric moisture measurement system for wood based materials. The measurement principle is based on combining the Loss on Drying (LoD) method with complementary water loss detection systems. In our setup, air flows throu
Publikováno v:
International Journal of Thermophysics. 35:668-680
Industrial grade platinum resistance thermometers were calibrated in the temperature range from $$200\,^{\circ }\mathrm{C}$$ to $$700\,^{\circ }\mathrm{C}$$ . Both wire-wound and thin-film sensor-based thermometers were investigated. The purpose of t
Publikováno v:
Högström, R, Korpelainen, V, Riski, K & Heinonen, M 2010, ' Atomic force microscopy studies of surface contamination on stainless steel weights ', Metrologia, vol. 47, no. 6, pp. 670-676 . https://doi.org/10.1088/0026-1394/47/6/006
The SI unit of mass will probably be redefined within the next few years using an invariable natural constant. Nevertheless, dissemination of the kilogram will still be realized by weighing using physical weights prone to contamination. Published dat
Publikováno v:
Kajastie, H, Rantanen, M, Riski, K & Semenoja, S 2005, ' An absolute pressure balance with a removable weight exchange system ', Measurement Science and Technology, vol. 16, no. 10, pp. N33-N37 . https://doi.org/10.1088/0957-0233/16/10/N01
The pressure balance used for MIKES barometer calibrations is a DH Instruments PG7601 for the range 5 kPa–350 kPa. The commonly used pressure range in barometer calibrations 850 hPa–1050 hPa has been automated by a removable weight exchange syste
Autor:
Heikki Kajastie, Kari Riski
Publikováno v:
Riski, K & Kajaste, H 2004, ' Study on temperature and density gradients in water for hydrostatic density determination ', Measurement Science and Technology, vol. 15, no. 9, pp. 1687-1693 . https://doi.org/10.1088/0957-0233/15/9/003
Temperature gradients were studied in two different pieces of density calibration equipment. Density is determined by hydrostatic weighing in water. The temperature of water and the surrounding air was determined with six temperature sensors. Also de
Autor:
Ville Tuhkanen, Kari Riski, Mikko Vähäsöyrinki, Jeremias Seppä, Leena Stenlund, Marko Pudas, Juha Röning
Publikováno v:
Stenlund, L, Riski, K, Seppä, J, Pudas, M, Vähäsöyrinki, M, Tuhkanen, V & Röning, J 2010, ' Traceable characterization of a bending millimetre scale cantilever for nanoforce sensing ', Measurement Science and Technology, vol. 21, no. 7 . https://doi.org/10.1088/0957-0233/21/7/075102
We have developed and characterized a force measuring system that is able to measure small forces down to 50 nN. The force measuring system and the characterizing method are described, thoroughly tested and analysed. The force measuring system consis
Publikováno v:
Metrologia. 51:128-128
The name of one author was omitted from the published article. Leena Stenlund should be added to the list of authors, with the same affiliation as the others.
Autor:
Jyrki Kiihamäki, Jani Karttunen, Kari Riski, P. Seppala, Teuvo Sillanpaa, Heikki Seppae, Aarne Oja
Publikováno v:
SPIE Proceedings.
A micro machined capacitive silicon scale has been designed and fabricated. It is intended for weighing masses on the order of 1 g at the resolution of about 1 ppm and below. The device consists of a micro machined SOI chip which is anodically bonded