Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Kai-Chun Su"'
Autor:
Kai-Chun Su, 蘇楷鈞
107
Since machine learning has been boosted significantly, especially for deep learning, by the development of hardware, a considerable amount of arduous task, like image classification and segmentation, can be solved by machine even with higher
Since machine learning has been boosted significantly, especially for deep learning, by the development of hardware, a considerable amount of arduous task, like image classification and segmentation, can be solved by machine even with higher
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/eu64m5
Autor:
Kai-Chun Su, 蘇凱群
92
In this study, a novel Micro-Electrode Biochip for Immunoassay was designed and fabricated by using MEMS (Micro Electro-Mechanical Systems) technique. The characteristics of Micro-Electrode Biochip with a capacity of efficient informative nan
In this study, a novel Micro-Electrode Biochip for Immunoassay was designed and fabricated by using MEMS (Micro Electro-Mechanical Systems) technique. The characteristics of Micro-Electrode Biochip with a capacity of efficient informative nan
Externí odkaz:
http://ndltd.ncl.edu.tw/handle/h4za7b
Publikováno v:
Biomedical Microdevices. 9:761-768
This study focuses on the design and experimental verification of an electroporation (EP) microchip system for the transfection of zebrafish (Danio rerio). For generating suitable pulses, a circuit is used to provide voltages between 0 and 700 V, wit
Publikováno v:
Sensors and Actuators B: Chemical. 117:451-456
This study focused on the development of an electro-immunosensing (EIS) microchip for real-time measurement of antibody–antigen recognition in immunoassay. Instead of the enzyme being conjugated with a secondary antibody for detection, the process
Publikováno v:
Materials Science Forum. :661-666
This study demonstrated that DNA associated with magnetic nanoparticles can be attracted to specific areas of cell surfaces under magnetic fields, which highly increased the DNA concentration at specific areas and further enhanced the gene transfecti
Publikováno v:
IEEE International Conference on Mechatronics, 2005. ICM '05..
This study was focused on the design and experimental verification of an electroporation (EP) biochip for transgenic zebrafishes (Danio rerio). For generating suitable pulses, a lab-built circuit was designed to provide suitable voltages (0~200 V) an
Publikováno v:
IEEE International Conference on Mechatronics, 2005. ICM '05; 2005, p799-804, 6p
Publikováno v:
Biomedical Microdevices; Oct2007, Vol. 9 Issue 5, p761-768, 8p