Takatugu Shimono, Koji Kawahito, Kimitaka Tasai, Yasuhisa Ohara, George Damm, Robert Benkowski, Satoshi Ohtsubo, Julie Glueck, Kenzo Makinouchi, Yoshiyuki Takami, Yukihiko Nosé, George P. Noon, Tadashi Nakazawa
Publikováno v:
Artificial organs. 20(5)
Since 1991, in our laboratory, a pivot bearing-supported, sealless, centrifugal pump has been developed as an implantable ventricular assist device (VAD). For this application, the configuration of the total pump system should be relatively small. Th
Autor:
Kazumi Mizuguchi, Kozo Naito, Julie Glueck, Yasuhisa Ohara, Setsuo Takatani, Yukihiko Nosé, Kenzo Makinouchi, George P. Noon, George Damm, Yukihiko Orime, Ichiro Sakuma, Kimitaka Tasai
Publikováno v:
Artificial Organs. 17:599-604
A seal-less centrifugal pump aiming for long-term circulatory support has been developed. In this model, shaft seals that cause thrombus formation and blood leakage were eliminated. A brushless direct current motor was incorporated as a driving unit,
Autor:
Kimitaka Tasai, Hiroshi Asajima, Takehiro Kubota, Naotaka Saito, Takahiko Saito, Masatoshi Motohashi, Shouji Matsushima
Publikováno v:
International Journal of Cardiology. 135:e27-e29
Left main coronary artery atresia is an extremely rare disease. Differential diagnosis of left main coronary artery atresia from atherosclerotic occlusion of left main coronary artery is difficult even if performing invasive coronary angiography. We
Autor:
Yasuhisa Ohara, Paul A. Svejkovsky, Yukihiko Nosé, Kimitaka Tasai, Kozo Naito, George Damm, Greg S. Aber, Kazumi Mizuguchi, Richard J. Bozeman, Jim W. Bacak, Setsuo Takatani, Kenzo Makinouchi, Michael E. DeBakey, George P. Noon, Yukihiko Orime
Publikováno v:
Artificial Organs. 18:650-656
The effect of hematocrit (Ht) on in vitro hemolysis test results (i.e., index of hemolysis) was evaluated using a Baylor/NASA prototype axial flow pump. Red blood cell suspensions of six different Ht (5, 10, 15, 20, 30, 40%; n = 30) were prepared and
Autor:
Yasuhisa Ohara, Kenzo Makinouchi, Yukihiko Orime, Kimitaka Tasai, Julie Glueck, Yukihiko Nosé, Byron Sutherland, Kozo Naito, Takatsugu Shimono, Setsuo Takatani
Publikováno v:
Artificial Organs. 18:673-679
The Baylor C-Gyro Pump Eccentric Inlet Port Models (C1E) have been developed aiming for a long-term centrifugal ventricular assist device (VAD) as well as a cardiopulmonary bypass pump. The eccentric inlet port models are characterized by their uniqu
Autor:
Yasuhisa Ohara, George P. Noon, Kozo Naito, Setsuo Takatani, Julie Glueck, Yukihiko Nosé, Yukihiko Orime, Kimitaka Tasai, George Damm, Jens T. Wernicke, Dirk Meier, Kazumi Mizuguchi
Publikováno v:
ASAIO Journal. 40:M499-M505
To analyze the flow patterns of the left blood chamber of the Baylor total artificial heart (TAH) and to evaluate influences of the inflow valve angle to the flow patterns, flow visualization studies were performed. The inflow valve angle of the left
Autor:
Kenzo Makinouchi, Setsuo Takatani, Yasuhisa Ohara, George P. Noon, Yukihiko Nosé, Kazumi Mizuguchi, Kimitaka Tasai, Takatsugu Shimono, Julie Glueck, Yukihiro Matsuda, Yukihiko Orime, Kozo Naito
Publikováno v:
Artificial Organs. 18:54-72
Properly planned in vitro and in vivo studies are mandatory to validate blood pump performance. However, standard procedures for in vitro and in vivo tests of total artificial heart (TAH) performance still do not exist. At Baylor College of Medicine,
Autor:
Yasuhisa Ohara, George P. Noon, Kazumi Mizuguchi, Julie Glueck, Yukihiko Nosé, George Damm, Kenzo Makinouchi, Yukihiko Orime, Kozo Naito, Kimitaka Tasai, Setsuo Takatani, Takatsugu Shimono
Publikováno v:
Artificial Organs. 18:17-24
We have developed a compact, seal-less, all-purpose centrifugal pump, the Baylor C-Gyro pump, which is intended as a long-term ventricular assist device (VAD) as well as a cardiopulmonary bypass pump. In attaining this goal, we began with eliminating
Autor:
YUKIHIKO ORIME, SETSUO TAKATANI, YASUHISA OHARA, KIMITAKA TASAI, KOZO NAITO, KAZUMI MIZUGUCHI, GEORGE DAMM, JULIA GLUECK, DAVID SUMMERS, GEORGE P. NOON, YUKIHIKO NOSEA, MICHAEL E. DEBAKEY
Publikováno v:
ASAIO Journal. 39:M172-M176
To test the durability of each part or assembled component of the Baylor-ABI total artificial heart (TAH), the authors performed an endurance test under severe conditions. The TAH was immersed in a saline bath at 42 degrees C, which is 4-5 degrees C
Autor:
Yukihiko Orime, Motomi Shiono, Kimitaka Tasai, George Damm, Yukihiko Nosé, Yasuhisa Ohara, Yukiyasu Sezai, Setsuo Takatani, George P. Noon, Julie Glueck
Publikováno v:
Heart Replacement ISBN: 9784431670223
A totally implantable electromechanical total artificial heart (TAH) system has been developed in our institute. This pump is very small (outer diameter, 97 mm; central thickness, 83 mm; and weight, 620 g), demonstrating a good anatomical fit in the
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::700f340fc6887373cfd234c3e8d386f7
https://doi.org/10.1007/978-4-431-67020-9_12
https://doi.org/10.1007/978-4-431-67020-9_12