Zobrazeno 1 - 10
of 84
pro vyhledávání: '"K.W.E. Denson"'
Publikováno v:
Clinical & Laboratory Haematology. 3:109-115
Summary Four generations of a newly discovered kindred suffering from congenital factor VII deficiency have been studied. The abnormality was transmitted as an autosomal recessive character and resulted in homozygotes with < 1%, factor VII procoagula
Publikováno v:
The Lancet. 310:1249-1252
In 50 women with high-risk pregnancies, increased factor-VIII consumption, as estimated by the difference between the levels of factor-VIII-related antigen and factor-VIII clotting activity, correlated with the severity of pre-eclampsia, particularly
Autor:
T Wilkins, K.W.E. Denson
Publikováno v:
Clinical & Laboratory Haematology. 2:311-316
Summary The simplified three manipulation two-stage assay for factor VIII coagulant activity has been compared manually and in a semi-automated method using the Coag-a-Pet instrument of General Diagnostics.
Autor:
K.W.E. Denson
Publikováno v:
Thrombosis Research. 10:107-119
It is suggested that the ratio of factor VIII-related antigen/factor VIII biological activity may be a useful indicator of hypercoagulability or intravascular coagulation, and a measure of the efficacy of steady state anticoagulation. The ratio was s
Autor:
K.W.E Denson
Publikováno v:
Thrombosis and Haemostasis. 35:314-323
SummaryThe clotting of C. V. Helleri plasma is not accelerated by the factor X activator or throm-bin-like enzymes from its own venom. Clotting of the plasma is accelerated by the factor X activator from Russell’s viper venom, but not by the thromb
Autor:
K.W.E. Denson
Publikováno v:
Thrombosis Research. 8:351-360
Echis Carinatus venom contains both an activator of factor X and a prothrombin activator, which have been separated by column chromatography of the crude venom on DEAE cellulose. The prothrombin activator, unlike the Taipan venom, does not require th
Autor:
K.W.E. Denson, K.K. Das
Publikováno v:
Pathophysiology of Haemostasis and Thrombosis. 1:223-228
A screening test has been investigated for detecting factor VIII antibodies, based on the observation of Strauss and Merler that a lower initial concentration of factor VIII detects weaker antibodies. At an initial factor VIII concentration of 0.1 β
Publikováno v:
Oral Presentations.
Four generations of a kindred suffering from congenital Factor VII deficiency have been studied. The defect is transmitted as an autosomal recessive character with homozygotes having < 1% Factor VII procoagulant activity, and heterozygotes between 20
Autor:
K.W.E. Denson
Publikováno v:
Clinical and laboratory haematology. 10(3)
A more sensitive or higher concentration of rabbit brain thromboplastin does not result in greater accuracy and precision of results in oral anticoagulant therapy and is unable to mimic the PIVKA sensitivity of human brain. In terms of International