Zobrazeno 1 - 10
of 95
pro vyhledávání: '"K.L. Swinth"'
Autor:
Joseph C. McDonald, J. Böhm, H.-M. Kramer (Invited), K.L. Swinth, W.G. Alberts, C.G. Soares, I.M.G. Thompson (Invited)
Publikováno v:
Radiation Protection Dosimetry. 86:87-105
One of the activities of the International Organization for Standardization (ISO) is the preparation and revision of standards specifying the requirements for photon, beta and neutron reference radiations to be used in radiation protection for the ca
Autor:
K.L. Swinth, R.E. Faw
Publikováno v:
Radiation Protection Dosimetry. 78:213-220
Fluence-to-absorbed dose conversion coefficients and their variations with angle of incidence have been computed for monoenergetic beams of beta panicles incident on rod and pillar ICRU tissue phantoms. Such phantoms are used for calibration of ring
Autor:
K.L Swinth, R.E. Faw
Publikováno v:
Radiation Protection Dosimetry. 72:5-10
Fluence-to-absorbed dose conversion coefficients and their variations with angle of incidence have been computed for monoenergetic beams of electrons incident on rod and pillar ICRU-tissue phantoms used for calibration of ring and wrist or ankle dose
Autor:
D.R. Sisk, K.L. Swinth
Publikováno v:
Radiation Protection Dosimetry. 39:149-156
Dose rate monitoring for weakly penetrating radiation is often attempted by modifying conventionally designed survey meters. This has led to an understanding of the requirements for such monitoring, but has not resulted in commercially available inst
Publikováno v:
Radiation Protection Dosimetry. 39:67-70
Autor:
Daniel R. Sisk, K.L. Swinth
Publikováno v:
Radiation Protection Dosimetry. 37:25-29
A technique was developed to calculate the response of cylindrical ion chambers to large area beta sources. Beta particles were simulated as vectors originating from a point on a source plane. Response calculations were performed for various source-p
Autor:
K.L. Swinth, D.R. Sisk
Publikováno v:
IEEE Transactions on Nuclear Science. 37:907-910
It is noted that available survey instruments do not have the beta measurement characteristics needed for accurate dose rate assessments. Such instruments have severe angular and energy dependence. In addition, beta measurements often require correct
Publikováno v:
IEEE Transactions on Nuclear Science. 37:902-906
The environmental and radiation responses of the active personnel dosimeter/superheated drop detector (APD/SDD) combination have been evaluated at the Pacific Northwest Laboratory (PNL) for the US Department of Energy's Neutron Measurement and Evalua
Autor:
K.L. Swinth
This report describes considerations for application of the electronic dosimeter (ED) as a measurement device for the dose of record (primary dosimetry). EDs are widely used for secondary dosimetry and advances in their reliability and capabilities h
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::9e853918f11a84477aaafe2c9b6a4709
https://doi.org/10.2172/564200
https://doi.org/10.2172/564200
Pacific Northwest Laboratory and Westinghouse Hanford Company tested six models of commercially available alpha continuous air monitors (CAMs): the Canberra Alpha Sentry, Eberline Alpha 6A-1, Merlin Gerin A-CAM, NE America CAM1A, SAIC/RADeCO Model 45