Zobrazeno 1 - 10
of 297
pro vyhledávání: '"K.D. Srivastava"'
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 24:2746-2754
Electrical insulation performance of compressed gas insulated switchgear (GIS) is adversely affected by metallic particle contaminants with a loss of up to 90% of the gas dielectric strength. Such particles play a crucial role in determining the syst
Publikováno v:
IEEE Transactions on Power Delivery. 25:1573-1579
Multiphase transmission line representations are used in the high-frequency modelling of transformer windings for the estimation of fast overvoltages as well as in the analysis of diagnostic methods used in condition monitoring. Due to the large dens
Publikováno v:
IEEE Transactions on Power Delivery. 25:1564-1572
Accurate high-frequency simulation of power transformer windings often involves detailed turn-by-turn modeling of the winding structure. The most detailed models currently in existence use multiphase transmission systems with frequency-dependent loss
Publikováno v:
IEEE Transactions on Power Delivery. 24:996-1003
Online transformer condition monitoring techniques based on transfer function methods, such as transmission-line diagnostics and swept frequency-response analysis, require the injection of a known test signal into the transformer. On larger power tra
Publikováno v:
Electric Power Systems Research. 79:871-877
Transfer function signatures are commonly used in condition monitoring analysis to give early indications of winding movement in power transformers. This paper presents a comparison of the use of trans-admittance (frequency response analysis, FRA), p
Publikováno v:
International Journal of Applied Electromagnetics and Mechanics. 29:117-129
Electric field effect on metallic particle contamination in a common enclosure gas insulated busduct
Autor:
G. V. Nagesh Kumar, K.D. Srivastava
Publikováno v:
IEEE Transactions on Dielectrics and Electrical Insulation. 14:334-340
Sulphur hexaflouride (SF6) is generally found to be very sensitive to field perturbations such as those caused by conductor surface imperfections and by conducting particle contaminants. A study of CIGRE group suggests that 20% of failures in gas ins
Publikováno v:
IEEE Transactions on Power Delivery. 20:1930-1938
FRA tests in the frequency range up to 10 MHz were investigated using simulations and measurements. It was found that the FRA test was more sensitive to changes in the transformer at frequencies above 1 to 3 MHz than at lower frequencies. However, th
Publikováno v:
Electric Power Components and Systems. 33:575-586
Electrical insulation performance of compressed gas insulated switchgear (GIS) and gas insulated transmission line (GITL) system is adversely affected by metallic particle contaminants. Dielectric coatings help to improve the insulation performance i
Publikováno v:
IEEE Electrical Insulation Magazine. 20:5-12
This paper presents data from a study conducted to identify the key factors that contribute to frequency response analysis (FRA) measurement results. The results show that the lower the shunt impedance, the higher the sensitivity of the FRA measureme