Zobrazeno 1 - 10
of 12
pro vyhledávání: '"K. T. den Boer"'
Publikováno v:
Surgical endoscopy, 16(3), 492-499. Springer New York
The increased technological complexity of surgery and the growing importance of quality assessment demand objective analysis of the surgical process. However, until now no standard method existed for analyzing the peroperative process. In this articl
Publikováno v:
Journal of laparoendoscopic & advanced surgical techniques. Part A, 10(6), 325-330. Mary Ann Liebert Inc.
PURPOSE: To compare three techniques of establishment of pneumoperitoneum for efficacy: the Veress needle/first trocar, the Hasson trocar, and a newly developed modified blunt trocar, the TrocDoc. PATIENTS AND METHODS: Between June and December 1999,
Publikováno v:
British journal of surgery, 86(7), 951-955. John Wiley and Sons Ltd
Background Advanced technology is being introduced rapidly into laparoscopic procedures, frequently without an accurate evaluation of its functioning. In this study, standardized time–motion analysis was applied to evaluate the peroperative surgica
Publikováno v:
Surgical endoscopy, 13(9), 869-873. Springer New York
BACKGROUND: Sensory feedback is reduced considerably in minimally invasive procedures by the interposition of instruments, causing loss of direct manual contact with the tissue. The purpose of this study was to evaluate the feedback quality of commer
Publikováno v:
IFAC Proceedings Volumes. 31:503-507
This paper presents newly designed laparoscopic forceps and describes the evaluation of the man-machine interface performance. Careful mechanical design has led to a purely mechanical instrument with excellent intrinsic feedback capacity, thus omitti
Publikováno v:
Journal of Laparoendoscopic & Advanced Surgical Techniques, 11 (3), 2001
Journal of laparoendoscopic & advanced surgical techniques. Part A, 11(3), 149-155. Mary Ann Liebert Inc.
Journal of laparoendoscopic & advanced surgical techniques. Part A, 11(3), 149-155. Mary Ann Liebert Inc.
Introduction: Laparoscopic surgery is particularly known for its complex technique, which calls for operative analysis of laparoscopic instruments. This study investigates the opinion of experts about clinical problems with instruments occurring duri
Publikováno v:
Journal of Laparoendoscopic and Advanced Surgical Techniques, 10 (6), 2000
Journal of laparoendoscopic & advanced surgical techniques. Part A, 10(6), 331-335. Mary Ann Liebert Inc.
Journal of laparoendoscopic & advanced surgical techniques. Part A, 10(6), 331-335. Mary Ann Liebert Inc.
Background and Purpose: During minimally invasive procedures, an assistant controls the camera and often a laparoscopic grasper. Ideally, the surgeon should be able to manipulate the instruments because the indirect way of control complicates the sur
Publikováno v:
Surgical endoscopy, 15(5), 497-503. Springer New York
OBJECTIVES: This study demonstrates the application of time-action analysis to the evaluation of task performance of diagnostic laparoscopy with laparoscopic ultrasonography. METHODS: The first 25 diagnostic laparoscopies with laparoscopic ultrasonog
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::3be12d751f7904211b1f9beb0ff57eeb
https://pure.amc.nl/en/publications/analysis-of-the-quality-and-efficiency-in-learning-laparoscopic-skills(b5c5285e-ff3e-4634-93ef-6b71c396084a).html
https://pure.amc.nl/en/publications/analysis-of-the-quality-and-efficiency-in-learning-laparoscopic-skills(b5c5285e-ff3e-4634-93ef-6b71c396084a).html
Publikováno v:
Journal of Laparoendoscopic and Advanced Surgical Techniques, 10 (1), 2000
Journal of laparoendoscopic & advanced surgical techniques. Part A, 10(1), 47-53. Mary Ann Liebert Inc.
Journal of laparoendoscopic & advanced surgical techniques. Part A, 10(1), 47-53. Mary Ann Liebert Inc.
Purpose: To determine the most efficient technique for performing a colectomy, we used the methodology of time-motion analysis. Methods: The efficiency of five hand-assisted and six regular laparoscopic colectomies and one open colectomy, performed b
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::f0a2c45aa6137d90dfa3a22967924fc1
http://resolver.tudelft.nl/uuid:6e3d6d2f-d71e-4880-99e0-fabaef412c67
http://resolver.tudelft.nl/uuid:6e3d6d2f-d71e-4880-99e0-fabaef412c67
Autor:
L. Th. de Wit, O.R.C. Busch, D. L. Gouma, W. A. Bemelman, J. F. M. Klaase, K. T. den Boer, Cornelis A. Grimbergen
Publikováno v:
Journal of laparoendoscopic & advanced surgical techniques. Part A, 10(4), 217-218. Mary Ann Liebert Inc.
Veress needle and trocar-related accidents have caused many surgeons to adopt the Hasson technique for establishment of pneumoperitoneum, but this technique also has drawbacks. A modification of the sharp trocar has been developed that overcomes the
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::7de119326bc10b2bb0ec7c5f4ca219aa
https://pure.amc.nl/en/publications/establishment-of-pneumoperitoneum-with-a-modified-blunt-trocar(a35d3f8a-dde7-4f62-8a65-899a515f6033).html
https://pure.amc.nl/en/publications/establishment-of-pneumoperitoneum-with-a-modified-blunt-trocar(a35d3f8a-dde7-4f62-8a65-899a515f6033).html