Zobrazeno 1 - 10
of 22
pro vyhledávání: '"K. Prabhakar Nayak"'
Publikováno v:
International Journal of Mobile Computing and Multimedia Communications. 8:14-26
Wireless Body Sensor Network with wearable and implantable body sensors have been grabbing lot of interests among the researchers and healthcare service providers. These sensors forward physiological data to the personnel at the hospital, doctor or c
Wireless Body Sensor Network with wearable and implantable body sensors have been grabbing lot of interests among the researchers and healthcare service providers. These sensors forward physiological data to the personnel at the hospital, doctor or c
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::23bbf59dc77b3834f64a7c27eb7548d0
https://doi.org/10.4018/978-1-5225-9863-3.ch028
https://doi.org/10.4018/978-1-5225-9863-3.ch028
Publikováno v:
IOP Conference Series: Materials Science and Engineering. 1119:012020
One of the potential applications of Wireless Sensor Network for improving the lifestyle of human beings is Wireless Body Sensor Network (WBSN). A dedicated health monitoring system is referred to as the Ubiquitous Health Monitoring (UHM) system cons
Publikováno v:
Biomedical Signal Processing and Control. 31:181-188
Three dimensional reconstruction is essential in accurate diagnosis of numerous spinal deformities which are 3D in nature. The stereo-radiographic reconstruction involving bi-planar X-rays is one of the most commonly used methods. Algorithms with ste
Publikováno v:
Journal of Digital Imaging. 29:226-234
Complex deformities of the spine, like scoliosis, are evaluated more precisely using stereo-radiographic 3D reconstruction techniques. Primarily, it uses six stereo-corresponding points available on the vertebral body for the 3D reconstruction of eac
Autor:
U. Rajendra Acharya, Sulatha V. Bhandary, E. Y. K. Ng, K. Prabhakar Nayak, Lim Wei Jie Eugene, Lim Choo Min, Kevin Noronha
Publikováno v:
Biomedical Signal Processing and Control. 15:18-26
Increase in intraocular pressure (IOP) is one of the causes of glaucoma which can lead to blindness if not detected and treated at an early stage. Glaucoma symptoms are not always obvious; hence patients seek treatment only when the condition progres
Publikováno v:
2017 2nd International Conference on Communication Systems, Computing and IT Applications (CSCITA).
Scoliosis is a 3D deformation of the human spine. It is evaluated using 3D stereo-radiographic reconstruction from the biplanar x-rays. The combined stereo-corresponding point and geometric (CSCPG) reconstruction algorithm is used for this purpose. T
Publikováno v:
Journal of The Institution of Engineers (India): Series B. 95:287-293
In this paper, an analytical and simulated approach has been developed for evaluating the performance of Bit Error Rate (BER) of Direct Sequence Spread Spectrum (DSSS). It is also demonstrated in this paper that how BER can be minimised using Rate Tr
Autor:
K. Prabhakar Nayak, Sulatha V. Bhandary, U. Rajendra Acharya, Kevin Noronha, Roshan Joy Martis
Publikováno v:
Biomedical Signal Processing and Control. 10:174-183
Glaucoma is a group of disease often causing visual impairment without any prior symptoms. It is usually caused due to high intra ocular pressure (IOP) which can result in blindness by damaging the optic nerve. Hence, diagnosing the glaucoma in the e
Autor:
Kevin Noronha, K. Prabhakar Nayak
Publikováno v:
Journal of Medical Imaging and Health Informatics. 3:494-501