Publikováno v:
X-Ray Spectrometry. 20:287-292
An XRF device using polarized x-rays for trace element analysis of rocks and soils has been developed. During a measuring time of 1000 s (two single measurements of 750 and 250 s, respectively), 36 elements with atomic numbers 22 ≤ Z ≤ 92 and det
Publikováno v:
Zeitschrift für Naturforschung B. 46:1200-1206
Normal coordinate analyses for all compounds of the series [MXnY6-1]z-, M = Ru, Rh, Os, Ir, Pt; Χ ≠ Y = F, Cl, Br; n = 0-6; z = 1-3, including the geometric isomers for n = 2, 3, 4 have been performed, based on a general valence force field. For t
Publikováno v:
Zeitschrift für Naturforschung A. 46:803-808
The electronic absorption spectra of the solid tetrabutylammonium salts of [OsClnBr6-n ]2-, n = 0-6, including the stereoisomers for n = 2, 3, 4, are measured at 10 K. The weak intraconfigurational excitations within the t2g 4, manifold of Os(lV) are
Publikováno v:
Zeitschrift für Naturforschung B. 45:283-289
The IR- and Raman spectra of the ten chloro-bromo-osmates(IV) [OsCl„Br6-n]2-, n = 0-6, including the geometrical isomers for n = 2, 3, 4 have been recorded at low temperature (80 K). The vibrational spectra of these complexes are completely assigne
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 349:292-294
As an alternative of using 6 Li-glass scintillators for neutron detection in time focusing geometry the effects of ZnS/ 6 Li scintillation material on the measuring efficiency will be discussed on example of the high resolution RTOF device FSS at GKS
Publikováno v:
ChemInform. 21
Publikováno v:
Isotopenpraxis Isotopes in Environmental and Health Studies. 26:341-342
The application of polarized X-rays in energy dispersive X-ray fluorescence analysis (EDXRF) is prooved to be one method for improvement the sensitivity of trace analysis at rock- and soil-samples. The use of a high power X-ray tube in connection wit
Publikováno v:
Isotopenpraxis Isotopes in Environmental and Health Studies. 22:225-232
A measuring device which allows the determination of small quantities of 235U in large measuring samples is described. For 235U-determination livo methods are used: — the measurement of fission neutrons resulting from the fission of 235U by irradia
Publikováno v:
Isotopenpraxis Isotopes in Environmental and Health Studies. 21:347-351
n-Silicon was produced by neutron transmutation doping from suitable p-Silicon, which was used to manufacture detector structures. It was pointed out, that these detectors are applicable to provide α-, β- and γ-spectrometry and counting at room te
Publikováno v:
Isotopenpraxis Isotopes in Environmental and Health Studies. 19:121-124
Es wird ein Meβverfahren beschrieben, das es gestattet, durch eine zewifache, aufeinanderfolgende Aktivierung der Probe mit Neutronen verschiedener Energieverteilung und Messung der Gammastrahlung der gebildeten kurzlebigen Spaltprodukte die Massen