Zobrazeno 1 - 10
of 292
pro vyhledávání: '"K. Gersonde"'
Publikováno v:
Journal of Materials Science: Materials in Medicine. 10:649-652
As a model for hydrogel-coated biomaterials, self-assembled monolayers of polyoxyethylene (POE) derivatives on sheets of polymeric biomaterials were prepared. The POE derivatives consisted of hydrophilic chains with different lengths and a long-chain
Publikováno v:
The International Journal of Artificial Organs. 21:216-224
This paper presents a new cardiac support device for left ventricular failure which consists of two inflatable bellows positioned dorsally and ventrally to the left ventricle. The implantable multichamber pump system (IMPS) is driven by a pneumatic p
Publikováno v:
The Thoracic and Cardiovascular Surgeon. 43:1-12
In this paper we present a therapeutic concept for the treatment of heart failure due to muscular inability to pump properly. The basic principle of this concept triggered numerous studies, then with the aim of cardiopulmonary resuscitation, back in
Publikováno v:
Isotopenpraxis Isotopes in Environmental and Health Studies. 28:81-84
Following intravenous injections of [15N]glycine (97 at.% 15N, 400 mg in 1.5 ml isotonic saline) to Lewis rats several organs were excised. The time courses of the 15N NMR spectral (40.55 MHz) were measured at 37°C after cold (4°C) or warm (37°C)
Publikováno v:
Magnetic Resonance in Medicine. 24:149-157
The dispersion (frequency dependence) of the spin-lattice relaxation time in the rotating frame, T1ρ, is considered for tissue characterization. Methods for the volume-selective determination of the proper T1ρ, dispersion and for imaging of paramet
Autor:
H. Kiesewetter, Gerhard Müller, Friedrich Jung, Sebastian Wolf, K. Gersonde, H Toonen, Ernst Wenzel, C. Mrowietz
Publikováno v:
Biomedizinische Technik/Biomedical Engineering. 35:195-204
Error analysis or the evaluation of the precision of microscopic measurements must distinguish between technical errors inherent in the measuring system, and biological variability. The technical error inherent in the overall system in the case of li
Publikováno v:
Journal of materials science. Materials in medicine. 10(10/11)
As a model for hydrogel-coated biomaterials, self-assembled monolayers of polyoxyethylene (POE) derivatives on sheets of polymeric biomaterials were prepared. The POE derivatives consisted of hydrophilic chains with different lengths and a long-chain
Publikováno v:
Biomedizinische Technik/Biomedical Engineering. :259-260
The larva of the midge Chironomus thummi thummi possesses two monomeric hemoglobins. HbIII and HbIV, with extensive sequence homology, which exhibit marked but differential Bohr effects (pH influence on ligand affinity). These Hbs serve as ideal mode
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::eb77876f1db83fcd3427ad1f6f230891
https://publica.fraunhofer.de/handle/publica/194338
https://publica.fraunhofer.de/handle/publica/194338
Publikováno v:
Endoscopic surgery and allied technologies. 3(4)
Current medical practice deals with a variety of multimodal information (X-ray film, ultrasound, CT, MR, ECG and EEG, laboratory results, medical records, etc.) Diagnosis and treatment demand an integrated view of this information including the patie