Zobrazeno 1 - 10
of 95
pro vyhledávání: '"K. Frohner"'
Publikováno v:
DMW - Deutsche Medizinische Wochenschrift. 114:855-860
120 of 272 consecutive patients (44%) with confirmed myocardial infarction reached hospital within three hours of onset of symptoms. Important delays were caused by the patients "treating" themselves with drugs (delay of 6.8 +/- 14.9 h) and/or other
Autor:
Emil Wessely, Konrad Steinbach, Michael Nürnberg, Oliver Merl, Andrea Podczeck, Christine Hief, Wilhelm Kaltenbrunner, K. Frohner
Publikováno v:
American Heart Journal. 127:1102-1106
The hemodynamic consequences of ventricular tachycardias are caused by cardiac and peripheral reactions. As a result, cardiac output and arterial pressure decrease. Even if the decrease is related to the tachycardia rate and left ventricular function
Publikováno v:
European Heart Journal. 12:796-799
To determine the electrophysiological properties of oral propafenone, 50 patients (39 male and 11 female, aged 31 to 80 years) with sustained ventricular tachycardia or ventricular fibrillation underwent serial electrophysiological drug testing, usin
Publikováno v:
Journal of Cardiovascular Electrophysiology. 1:320-325
A patient treated with the automatic implantable defibrillator exhibited serial inappropriate shacks during amiodarone-induced hyperthyroidism. This case illustrates the elective effectiveness of the AICD in the termination of ventricular tachyarrhyt
Publikováno v:
Pacing and Clinical Electrophysiology. 13:719-723
Radiofrequency ablation of the atrioventricular conduction system was attempted in a 63-year-old man with drug refractory atrial fibrillation. A total of 5 radiofrequency pulses (750 kHz, power setting: 25-50 W, pulse duration: 9-20 sec) were deliver
Autor:
M. Hubner, L. Müllauer, K. Frohner, K. Kofler, Christian Müller, P. Petzelbauer, B. Blaha, E. Poeschl, M. Kneussl, L. Dzirlo, K. Huber, Michael Gschwantler
Publikováno v:
Zeitschrift für Gastroenterologie. 43
Publikováno v:
Pacing and Clinical Electrophysiology. 18:1589-1591
We report a unique case of fluid penetration, 3 months after implantation, in the connector port of an automatic implantable cardioverter defibrillator (ICD) with transvenous subcutaneous lead system. The patient had coronary artery disease and recur
Publikováno v:
Wiener klinische Wochenschrift. 110(13-14)
The present study examined the perioperative mortality and morbidity and lead-related complications in patients who had a defibrillator with a transvenous lead system and subpectoral implantation of the generator. Fifty-four out of 57 consecutive pat
Autor:
A, Podczeck, C, Hief, G, Jakl, K, Frohner, M, Nürnberg, W, Kaltenbrunner, F, Veit, G, Laufer, K, Steinbach
Publikováno v:
Wiener klinische Wochenschrift. 107(16)
8 of 122 patients receiving an implantable cardioverter defibrillator (ICD) in our department since 1985 for the treatment of ventricular tachyarrhythmias were considered candidates for cardiac transplantation. In 6 of 8 patients, at least one succes
Autor:
A, Podczeck, C, Hief, F, Veit, G, Jakl, W, Kaltenbrunner, M, Nürnberg, K, Frohner, K, Steinbach
Publikováno v:
Zeitschrift fur Kardiologie. 83(5)
Due to technical improvement using the transvenous-subcutaneous approach for lead fixation for cardioverter-defibrillator implantation, the incidence of device implantation has extended enormously. While a significant lower perioperative mortality in