Zobrazeno 1 - 10
of 15
pro vyhledávání: '"K. B. Carter"'
Publikováno v:
Journal of Medical Engineering & Technology. 21:89-95
An artificial anal sphincter was designed to reproduce the normal physiology of the ano-rectum by flattening and angulating the bowel without causing crenation. It was shown in the laboratory that by eliminating crenation, occlusion pressure was even
Publikováno v:
Gut. 33:352-356
The effect of ispaghula husk on colonic motility of the right and left side was examined in 10 patients with left sided diverticular disease using an untethered pressure sensitive radiotelemetry capsule. After treatment, ispaghula husk reduced mouth
Publikováno v:
Somatic cell and molecular genetics. 25(3)
The frequent occurrence of human mutations at CpG dinucleotide sites has been attributed to cytosine methylation and hydrolytic deamination of the resulting 5-methylcytosine residue. Previously, we reported an unusually strong hotspot for spontaneous
Publikováno v:
The British journal of surgery. 83(1)
This study was performed with an In vitro model to assess the relative importance of sphincter pressure and anorectal angulation in maintaining faecal continence. Water and semisolid material were infused separately into porcine intestine compressed
Publikováno v:
Medical & Biological Engineering & Computing. 27:631-634
Publikováno v:
Journal of Medical Engineering & Technology. 7:136-139
There are a variety of different types of pneumatic tourniquets in constant use within the UK Health Service. These range from simple manually operated units to more complex gas-powered devices. Fatalities have occurred following the failure of pneum
Publikováno v:
Anaesthesia. 39:790-794
The use of the new Medishield anaesthetic gas scavenging system with ventilators in the Siemens-Elema Servo 900 series was investigated. It was discovered that this combination of equipment creates the hazard that a disconnexion in the patient breath
Autor:
A. M. Perry, K. B. Carter
Publikováno v:
Journal of Medical Engineering & Technology. 1:29-32
The assessment of a non-invasive technique for measuring deep body temperature is described. An experimental system, in which the insulating effect of subcutaneous fat thickness could be simulated, was designed to test the deep body thermometer (DBT)
Publikováno v:
Anaesthesia. 41:1236-1239
The performance of the Travenol infusor when used to administer an intravenous infusion of analgesic after surgery has been investigated. Mean flow was very similar to the manufacturer's quoted figure of 2 ml/hour, but there was a large interindividu
Autor:
M. M. Halliday, K. B. Carter
Publikováno v:
Journal of Medical Engineering & Technology. 2:310-312