Zobrazeno 1 - 8
of 8
pro vyhledávání: '"K. A. HULTQUIST"'
Autor:
H. M. Dann, C. S. Ballard, R. Suzuki, H.A. Tucker, K.W. Cotanch, K. M. Hultquist, R. J. Grant
Publikováno v:
Journal of Animal Science. 94:729-730
Autor:
A. RASZYNSKI, K. A. HULTQUIST, H. LATIF, J. SUSSMANE, M. SOLER, A. ALAM, J. BRAO, J. AMOR, D. KlLHEENEY, T. KOLOBOW, J. WOLFSDORF
Publikováno v:
ASAIO Journal. 39:M681-M685
Hybrid intratracheal pulmonary ventilation (h-ITPV) is a continuous flow ventilatory technique that uses a "reverse thruster" catheter to redirect the flow of gas away from the carina. We report here the use of h-ITPV in a pediatric patient with acut
Autor:
A, Raszynski, K A, Hultquist, H, Latif, J, Sussmane, M, Soler, A, Alam, J, Brao, J, Amor, D, Kilheeney, T, Kolobow
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992). 39(3)
Hybrid intratracheal pulmonary ventilation (h-ITPV) is a continuous flow ventilatory technique that uses a "reverse thruster" catheter to redirect the flow of gas away from the carina. We report here the use of h-ITPV in a pediatric patient with acut
Prolonged extracorporeal circulation without heparin. Evaluation of the Medtronic Minimax oxygenator
Publikováno v:
ASAIO journal (American Society for Artificial Internal Organs : 1992). 38(3)
Bleeding remains the most common complication of prolonged extracorporeal life support (ECLS). This study evaluated the Medtronic Minimax (Annaheim, CA) microporous oxygenator with the Carmeda Bio Active (heparin bonded) Surface (Stockholm, Sweden) f
Publikováno v:
Surgery. 112(1)
Systemic oxygen delivery (DO2) is normally four to five times higher than oxygen consumption (VO2), and VO2 is independent of DO2. If DO2 is decreased to less than twice VO2, a state of anaerobic metabolism and supply dependency occurs. Some authors
Publikováno v:
Zeitschrift fur Geburtshilfe und Perinatologie. 194(2)
During an animal study using five bastard dogs the hemodynamic relations during extracorporeal perfusion with an arteriovenous circuit and extracorporeal CO2 removal (ECCO2-R) were analyzed. We utilised a prototype circuit (Promed, West-Germany) whic
Autor:
T, Otsu, S I, Merz, K A, Hultquist, R J, Attorri, H L, Anderson, D E, Scheffler, A, Ahmad, R H, Bartlett
Publikováno v:
ASAIO transactions. 35(3)
The authors designed and tested a 14F outside diameter thin-walled double lumen catheter (DLC) for neonatal venovenous (VV) extracorporeal membrane oxygenation (ECMO). In vitro tests with water and dye solution showed capacity of the drainage lumen w
Publikováno v:
ASAIO transactions. 34(3)
Adult sized extracorporeal membrane oxygenation circuits were coated with Duraflo II chemical heparin bonding by Baxter-Bentley Laboratories. Five sheep were maintained on venovenous extracorporeal circulation for four days with no systemic anticoagu