Zobrazeno 1 - 10
of 369
pro vyhledávání: '"K R, Duncan"'
Vitamin E nicotinate is an ester of tocopherol (vitamin E) and niacin (vitamin B3). While this ester can be chemically synthesized, whether vitamin E nicotinate is formed from vitamin E and niacin in the biological system is unclear. Our previous met
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::91f78460388b943e9112840c6e4d7fd6
https://doi.org/10.1039/9781788016216-00088
https://doi.org/10.1039/9781788016216-00088
Autor:
Ian R. Johnson, Penny A. Gowland, Damian J. Tyler, Brian S. Worthington, Rachel J. Moore, K. R. Duncan, Philip N. Baker, Bryony K. Strachan
Publikováno v:
Placenta. 21:726-732
The aim of this study was to measure and portray blood movement in the placenta in vivo in normal and growth restricted pregnancies, using Intra Voxel Incoherent Motion (IVIM) magnetic resonance imaging. Thirteen patients with apparently normal healt
Autor:
Pawel F. Tokarczuk, K. R. Duncan, Penny A. Gowland, Philip N. Baker, Rachel J. Moore, P. Boulby, Bashar Issa, Richard Bowtell, Ian R. Johnson, Brian S. Worthington
Publikováno v:
Magnetic Resonance in Medicine. 43:295-302
This paper presents the first in vivo measurements of intravoxel incoherent motion in the human placenta, obtained using the pulsed gradient spin echo (PGSE) sequence. The aims of this study were two-fold. The first was to provide an initial estimate
Publikováno v:
The British Journal of Radiology. 73:190-194
Any differences in detailed paediatric assessment at 9 months of age in infants exposed to echo planar MRI in utero from 20 weeks gestation to term were investigated by performing a case controlled prospective observational study of 20 infants. They
Publikováno v:
Radiology. 210:197-200
To measure changes in normal fetal lung volume with increasing gestation by using echo-planar magnetic resonance (MR) imaging.Fifty-six singleton fetuses were examined longitudinally with respect to lung volume by using echo-planar MR imaging between
Autor:
Ian R. Johnson, Philip N. Baker, Penny A. Gowland, Susan T. Francis, Rachel J. Moore, K. R. Duncan
Publikováno v:
Placenta. 19:539-543
Echo-planar imaging (EPI) is a form of magnetic resonance imaging (MRI) which acquires images in milliseconds rather than minutes as with conventional MRI. The images produced using EPI are affected by the physiological environment in which the hydro
Autor:
Ren, Xuanbai1 (AUTHOR), Wei, Jiaying2 (AUTHOR), Luo, Xiaoli1 (AUTHOR), Liu, Yuansheng1 (AUTHOR), Li, Kenli1 (AUTHOR), Zhang, Qiang3,4 (AUTHOR), Gao, Xin5 (AUTHOR), Yan, Sizhe2 (AUTHOR), Wu, Xia2 (AUTHOR), Jiang, Xingyue2 (AUTHOR), Liu, Mingquan1 (AUTHOR), Cao, Dongsheng6 (AUTHOR), Wei, Leyi7,8 (AUTHOR), Zeng, Xiangxiang1 (AUTHOR) xzeng@hnu.edu.cn, Shi, Junfeng2 (AUTHOR) Jeff-Shi@hnu.edu.cn
Publikováno v:
Advanced Science. 7/10/2024, Vol. 11 Issue 26, p1-12. 12p.
Publikováno v:
The British Journal of Radiology. 71:549-551
Echo planar imaging is a form of MRI with short image acquisition times, which permits in utero fetal imaging without motion artefacts. Echo planar imaging has been used to measure accurately fetal organ volume and to assess placental function. Two s
Autor:
Philip N. Baker, K. R. Duncan, Bashar Issa, Rachel J. Moore, Ian R. Johnson, Penny A. Gowland
Publikováno v:
BJOG : an international journal of obstetrics and gynaecology. 112(1)
Objectives To compare fetal organ size measured using echo-planar magnetic resonance imaging and 2D ultrasound. To determine the relative accuracy with which each technique can predict fetal growth restriction. Design A cross sectional, observational
Autor:
K. R. Duncan, Philip N. Baker, Allan M. Z. Chang, Rachel J. Moore, Penny A. Gowland, Daljit Singh Sahota, Ian R. Johnson
Publikováno v:
Journal of the Society for Gynecologic Investigation. 8(5)
To quantify longitudinal increases in fetal, fetal liver, and fetal brain volume using echo-planar magnetic resonance imaging and to quantify the results using appropriate statistical modeling.Fifty-six singleton fetuses were studied using echo-plana