Zobrazeno 1 - 8
of 8
pro vyhledávání: '"K N, Dozorov"'
Publikováno v:
Вестник трансплантологии и искусственных органов, Vol 18, Iss 2, Pp 65-73 (2016)
The article describes the technology of remote patient monitoring and the parameters of circulatory assist device AVK-N as well as the advantages of said technology to improve the efficiency of personalized medicine in diagnosis and treatment of pati
Externí odkaz:
https://doaj.org/article/d64af26c6fb947c88673dd1e8f5cb0c6
Publikováno v:
Вестник трансплантологии и искусственных органов, Vol 17, Iss 1, Pp 97-102 (2015)
The article describes complex software to calculate the main parameters of the axial pump (pressure drop and flow rate) on the basis of an analysis of its technical characteristics (current consumption and pump speed). It is shown that the calculated
Externí odkaz:
https://doaj.org/article/c8109734f25740069c63f6697aa9de55
Autor:
G. P. Itkin, E. G. Konysheva, S. U. Shemakin, K. N. Dozorov, V. L. Kydinov, I. V. Bikov, S. V. Selishev
Publikováno v:
Вестник трансплантологии и искусственных органов, Vol 13, Iss 4, Pp 91-96 (2011)
The article presents a theoretical analysis of the dynamic interaction of the left ventricle assist axial pump and the cardiovascular system. It is shown the axial pumps are working in conditions «left ventricle- aorta» generates a pulsed flow. The
Externí odkaz:
https://doaj.org/article/148eddbf2130499fb938b4e947fde841
Publikováno v:
Вестник трансплантологии и искусственных органов, Vol 12, Iss 3, Pp 94-100 (2010)
We analyzed the dynamics of the interaction of rotary pump, connected to the scheme «the left ventricle – aor- ta», and left ventricle in norms and heart failure, using data obtained on the mock circulatory system. Adverse pumping states such as
Externí odkaz:
https://doaj.org/article/69c5dadacfa54fc4abb72ec24eb6756a
Publikováno v:
Biomedical Engineering.
Control of rotor blood pumps by rotor rotation rate should be adapted to the requirements of the patient’s body. Physiological control of rotor blood pumps is based on information about the blood circulation system. The sensors should not contact t
Publikováno v:
Biomedical Engineering.
Methods and results of tests of biomedical parameters of a new accessory circulation apparatus based on implantable axial blood pump are discussed in this work. Bench tests were directed toward determining energy parameters and pump-induced injury of
Publikováno v:
Meditsinskaia tekhnika. (6)
Publikováno v:
Meditsinskaia tekhnika. (6)
Development of a control unit and power source for an implantable assisted circulation pump is discussed. The device for left ventricle assistance was developed in the Shumakov Federal Scientific Center for Transplantology and Artificial Organs, Mosc