Zobrazeno 1 - 10
of 10
pro vyhledávání: '"K H, Wenger"'
Publikováno v:
Journal of Biomedical Materials Research. 48:528-533
The design requirements for bioabsorbable fracture fixation devices for specific applications are as yet unknown. Therefore, a range of initial mechanical properties and degradation kinetics may provide developers with additional choices for the desi
Publikováno v:
The Anatomical Record. 251:15-19
Background The purpose of this study was to thoroughly evaluate the relationship of possible mechanical and environmental conditions in the testing of spinal joint segments, including ambient-temperature exposure, accumulated test cycles, angular-def
Publikováno v:
The Anatomical Record. 247:542-555
Background The sheep spine is often used as a model for the human spine, although the degree to which these spines are anatomically comparable has yet to be categorically established. The purpose of this study was to investigate the characteristic an
Publikováno v:
Journal of Materials Science Materials in Medicine. 8:753-756
The biocompatibility and osseous integration of a new composite material made of polyurethane and a calcium silicophosphate ceramic was investigated in a loaded implant model in sheep and compared to that of commercially pure titanium. Six months aft
Publikováno v:
Clinical biomechanics (Bristol, Avon). 14(1)
To produce axial rotation of the cervical spine in vitro by coordinated application of eight simulated muscle forces.Biomechanical testing of the cervical spine by controlled pneumatics.Some muscle simulation experiments have been performed in vitro
Publikováno v:
Medical Image Computing and Computer-Assisted Intervention – MICCAI 2000 ISBN: 9783540411895
MICCAI
MICCAI
The number of robots in operation in the German-speaking orthopaedic community more than doubled last year, reflecting considerable excitement among patients and doctors over the prospects of improving the accuracy of endoprosthesis surgery in both t
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::2f91dd6866e2dc4924319509323e14ab
https://doi.org/10.1007/978-3-540-40899-4_125
https://doi.org/10.1007/978-3-540-40899-4_125
Publikováno v:
Journal of biomedical materials research. 48(4)
The design requirements for bioabsorbable fracture fixation devices for specific applications are as yet unknown. Therefore, a range of initial mechanical properties and degradation kinetics may provide developers with additional choices for the desi
New implants and new surgical approaches should be tested in vitro for primary stability in standardized laboratory tests in order to decide the most appropriate approach before being accepted for clinical use. Due to the complex and still unknown lo
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::24644329f3d923ad2eed863bfa6604a6
https://europepmc.org/articles/PMC3611233/
https://europepmc.org/articles/PMC3611233/
Publikováno v:
The Anatomical record. 247(4)
The sheep spine is often used as a model for the human spine, although the degree to which these spines are anatomically comparable has yet to be categorically established. The purpose of this study was to investigate the characteristic anatomical di
Publikováno v:
European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 6(2)
The availability of human cadaveric spine specimens for in vitro tests is limited and the risk of infection is now of vital concern. As an alternative or supplement, calf spines have been used as models for human spines, in particular to evaluate spi