Zobrazeno 1 - 10
of 44
pro vyhledávání: '"K G Heiple"'
Publikováno v:
The Journal of bone and joint surgery. American volume.
Three of our five cases and approximately one-half the cases reported were misdiagnosed at the time of original injury. Increased awareness of this lesion and alertness to the relationship of the radius and ulna on lateral roentgenograms of the wrist
Publikováno v:
Clinical orthopaedics and related research. (302)
When patellectomy is performed, the objectives should include restoration of a moment arm, centralization of the extensor mechanism, adequate range of motion, and cosmesis. The cruciate repair of the extensor mechanism described in this report has be
Autor:
G. M. Kotzar, D. T. Davy, V. M. Goldberg, K. G. Heiple, J. Berilla, R. H. Brown, A. H. Burstein
Publikováno v:
Journal of orthopaedic research : official publication of the Orthopaedic Research Society. 9(5)
Two telemeterized femoral components were implanted in two patients as part of normal total hip replacement procedures. The two components were instrumented to measure the three force components directed along: (a) the neck axis, (b) transverse to th
Publikováno v:
The Journal of Bone & Joint Surgery. 70:45-50
A telemeterized total hip prosthesis was implanted in one patient and force-data were obtained. Thirty-one days postoperatively, the magnitude of the joint-contact force during double-limb stance was 1.0 times body weight. During ipsilateral single-l
Publikováno v:
Journal of Biomechanical Engineering. 104:12-20
The age-related material properties of developing immature canine bone were determined for the femora, tibiae, humeri, radii, and ulnae in animals from 1 wk of age to maturity. These properties included bone geometry changes, material tissue properti
Publikováno v:
The Journal of Bone & Joint Surgery. 60:506-515
An intramedullary rod for the femur was designed and compared with rods commonly used. Its bending strength was increased 40 to 80 per cent and its torsional rigidity was increased 230 to 3,000 per cent compared with the other devices tested. In fort
Publikováno v:
Journal of biomechanical engineering. 103(4)
Structural properties of growing canine long bones were determined from three and four-point bending tests. Mechanical and geometric properties were found to follow a biphasic growth process, with a rapid increase in bending strength and moment of in
Publikováno v:
The Journal of bone and joint surgery. American volume. 63(5)
Thirteen total knee replacements of the semiconstrained type were performed in ten patients with classic hemophilia (factor-VIII deficiency) and followed for two to six and one-half years. The average age at operation was twenty-seven years. Preopera
Publikováno v:
The Journal of bone and joint surgery. American volume. 60(4)
An intramedullary rod for the femur was designed and compared with rods commonly used. Its bending strength was increased 40 to 80 per cent and its torsional rigidity was increased 230 to 3,000 per cent compared with the other devices tested. In fort
Autor:
P A, Lunseth, K G, Heiple
Publikováno v:
Clinical orthopaedics and related research. (139)
Thirty-eight children (39 hips) with septic arthritis have been reviewed in an effort to determine the factors most important to prognosis of the hip joint. The younger patients, 3 or more years later, had poorer results by roentgenographic classific