Zobrazeno 1 - 10
of 1 163
pro vyhledávání: '"K Eidmann"'
Publikováno v:
Europhysics Letters (EPL). 44:459-464
The absorption of soft X-rays by gold at density of ≈ 0.01 g/cm3 and temperature of ≈ 20 eV has been measured in the photon energy range of 50 to 300 eV. For that purpose, a thin gold foil tamped by carbon was heated by thermal X-rays generated i
Autor:
A. Saemann, K. Eidmann
Publikováno v:
Review of Scientific Instruments. 69:1949-1954
We characterize an x-ray spectrometer in the wavelength range 10–70 A. The instrument has been designed for the study of the soft x-ray emission from plasmas generated with intense sub-ps laser pulses. It uses a flat field reflection grating with 2
Autor:
Vladimir E. Fortov, K. S. Dyabilin, V. P. Smirnov, E. V. Grabovskij, K. Eidmann, Maxim Lebedev
Publikováno v:
Physics Letters A. 240:73-76
An intense soft X-ray pulse of radiation ≈1 TW/cm2 generates in low (less than 50 mg/cm3) density foam nonlinear radiative heat waves, which propagate with a velocity several times higher than the sound velocity. A foam density of 5 mg/cm3 was achi
Autor:
F. Perrot, H. Merdji, C. Chenais-Popovics, J. C. Gauthier, Thomas Blenski, T. Mißalla, K. Eidmann
Publikováno v:
Physical Review E. 57:1042-1046
We present measurements of the samarium $(Z=62)$ $M$-shell absorption band around 11 \AA{} (1.1 keV) at electron temperatures between 5 and 20 eV. Using point projection absorption spectroscopy, we measured the absolute transmission of an x-ray probe
Publikováno v:
Journal of X-ray science and technology. 4(1)
We describe a XUV spectrometer for the study of dense hot microplasmas at wavelengths between ≈50 and ≈300 Å. It uses a commercially fabricated grazing incidence flat-field reflection grating with 1200 grooves per millimeter. The spectral resolu
Publikováno v:
Journal of X-Ray Science and Technology. 4:8-17
We describe a XUV spectrometer for the study of dense hot microplasmas at wavelengths between ≈50 and ≈300 A. It uses a commercially fabricated grazing incidence flat-field reflection grating with 1200 grooves per millimeter. The spectral resolut
Autor:
Michael Shultz, David Neely, Andrew MacFee, R. Sigel, K. Eidmann, T. Löwer, J. Massen, J. Meyer-ter-vehn, G. D. Tsakiris, S. Witkowski, Andre Richard, D. Wang
Publikováno v:
The Review of Laser Engineering. 21:95-108,113
Autor:
A. S. Shikanov, M.N. Yakimenko, Alexander A. Rupasov, D.A. Fedin, K. Eidmann, Rustem V. Fedorchuk, M. O. Koshevoi, Yu. Alexandrov, M.R. Shpol'sky, Violetta A. Murashova
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 308:343-346
An investigation of the sensitometric characteristics of X-ray films RAR 2497, SB-2, 101-01 (Kodak), D-7 (Agfa-Gevaert) and UFSh-0 (GNIIKhFP) has been carried out. These films are widely used in scientific research with different types of X-ray sourc
Autor:
K Eidmann
Publikováno v:
Journal of X-Ray Science and Technology. 2:259-273
Publikováno v:
Journal of X-Ray Science and Technology. 2:259-273
Gold pinhole transmission gratings fabricated by Heidenhain GmbH primarily for the purpose of studying the radiation of intense soft x-ray sources have been tested with the synchrotron radiation of BESSY. Typical results for the spectral dependence o