Zobrazeno 1 - 10
of 13
pro vyhledávání: '"K E Leopold"'
Publikováno v:
Journal of the Pediatric Infectious Diseases Society. 10:S12-S12
Background Candida species are the most common cause of fungal infection in hospitalized patients. Patients with candidemia are at risk of developing disseminated infection. Studies in adults have described risk factors for disseminated candidiasis i
Autor:
K. E. Leopold, R. S. Taylor
Publikováno v:
Review of Scientific Instruments. 65:3621-3627
A novel preionization technique which uses a surface corona discharge to produce preionization electrons for the controlled low jitter breakdown of a main corona‐gap preionizer is described. The pre‐preionization scheme has been used to reliably
Autor:
K. E. Leopold, Roderick S. Taylor
Publikováno v:
Applied Physics B Lasers and Optics. 59:479-508
A review is presented on the use of magnetic-spiker circuits to electrically excite rare-gas-halide and CO2 gas-discharge lasers. The design and operation of the diode, switch, overshoot, and charge modes of magnetic-spiker excitation will be describ
Publikováno v:
Applied Physics Letters. 59:525-527
Continuous cw (B→X) excimer fluorescence has been obtained at the KrCl, KrF, XeCl, and XeF wavelengths, using longitudinal direct current (dc) electrical excitation at current levels up to l A and gas pressures as high as 400 Torr. Electrical power
Autor:
K. E. Leopold, R. S. Taylor
A simple surface corona discharge excitation technique has been used to generate high repetition rate, high average power rare gas halide UV lamp radiation. The lamp exhibited reliable performance with very low jitter and high shot to shot reproducib
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::99039f47d8b1cf0accad91d69d61013e
https://doi.org/10.1063/1.1147022
https://doi.org/10.1063/1.1147022
Autor:
R. S. Taylor, K. E. Leopold
Publikováno v:
Review of Scientific Instruments. 63:4467-4468
Magnetic‐spiker sustainer technology has been used to generate pulsed TEA‐CO2 laser outputs of ∼2 J from ultrawide aperture (8 cm), small electrode gap (1 cm) discharges with a laser efficiency of 10.6%.
Publikováno v:
Applied Physics Letters. 30:635-637
A scalable uv‐preionized transverse discharge XeF laser has been operated at pressures up to 5 atm. uv output energies in excess of 250 mJ with a minimum pulse duration of less than 20 ns have been obtained from an active volume of 0.18 liter.
Autor:
R. S. Taylor, K. E. Leopold
Publikováno v:
Applied Physics Letters. 47:81-83
XeCl laser pulse durations of 1.5 μs (full width at half‐maximum) have been obtained using a recently developed UV‐preionized magnetically induced pulser laser excitation scheme.
Publikováno v:
Conference on Lasers and Electro-Optics.
Publikováno v:
Conference on Lasers and Electro-Optics.