Zobrazeno 1 - 10
of 45
pro vyhledávání: '"K, Tanpowpong"'
Autor:
K, Tanpowpong, C, Chiratthiti
Publikováno v:
Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 84(12)
The Ramathibodi nasal filter was specially designed as a personal respiratory protective device. It was attached to a simulated human airway composed of a nasal and pharyngeal model, airway passage and lung model machine. The system was run in a lase
Autor:
V, Praneetvatakul, B, Kulapaditharom, S, Kunachak, K, Tanpowpong, C, Euswas, W, Cheewaruangroj, C, Chintrakarn, T, Bhongmakapat
Publikováno v:
Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 84(3)
To present data on ten years' experience in CO2 laser surgery and associated complications among otorhinolayngologic patients.The study involved examining records of otorhinolaryngologic patients who underwent CO2 laser operations during a 10-year pe
Autor:
K, Tanpowpong
Publikováno v:
Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 83(11)
Intranasal, hollow, cylindrical, medical grade, silicone stent with two layers and one layer of half face mask outer filter at each end was tested with different concentrations of laser smoke particles. A single pulse mode of carbon dioxide laser smo
Autor:
K, Tanpowpong
Publikováno v:
Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 83(9)
Nasal model and lung model machine simulated human respiratory situation with cyclical air flow rate of 2 1/min. They were used to evaluate filtration efficacy of filters in an intranasal stent for laser smoke particles in the Otolaryngology Departme
Autor:
A, Chuansumrit, P, Isarangkura, P, Angchaisuksiri, N, Sriudomporn, K, Tanpowpong, P, Hathirat, L N, Jorgensen
Publikováno v:
Haemophilia : the official journal of the World Federation of Hemophilia. 6(2)
The efficacy of recombinant activated factor VII (rFVIIa, NovoSeven) in five Haemophiliacs (four Haemophilia A, one Haemophilia B), with high inhibitors ranging from 70 to 1900 Bethesda units, was evaluated. The treatment regimen was divided into two
Autor:
K, Tanpowpong
Publikováno v:
Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 83(1)
Intranasal, hollow, cylindrical, medical grade and silicone stent with two outer layers face mask filters at both ends was proposed for atmospheric suspended particulate matter prevention. The personal respiratory protective device efficacy was done
Autor:
K, Tanpowpong
Publikováno v:
Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 83(2)
A Millipore filter with 0.22 micron pore size and a Whatman grade 1 filter with11 microns particle retention were used to capture laser smoke particle mimic atmospheric suspended particulate matter. The experiment was conducted at the Department of O
Autor:
K, Tanpowpong
Publikováno v:
Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 81(8)
The experimental study of intranasal synthetic filter with stent was tried to decrease suspended particulate matter for human respiratory tract. Facial mask or surgical mask were evaluated. Nasal vestibular size in Thai adults was estimated. Differen
Publikováno v:
Journal of the Medical Association of Thailand = Chotmaihet thangphaet. 77(7)
Neck mass after the tracheostomy is a rare complication. A case report of pseudocyst at the left paratracheal area was presented and this has not yet been reported in the English literature. We proposed the pathophysiology of this condition and preve
Autor:
R B, Karasic, D J, Beste, S C, To, W J, Doyle, S W, Wood, M J, Carter, A C, To, K, Tanpowpong, C D, Bluestone, C C, Brinton
Publikováno v:
The Pediatric infectious disease journal. 8