Zobrazeno 1 - 10
of 309
pro vyhledávání: '"K, Schwieger"'
Publikováno v:
In Injury 2009 40(7):767-771
Publikováno v:
Veterinary and Comparative Orthopaedics and Traumatology. 21:185-194
Summary Objective: To compare the stiffness and strength of AO bone plates (DCP, LC-DCP, VCP, RCP, and LP) and the Clamp-Rod Internal Fixation System (CRIF). Study design: In vitro. Sample size: 12 individual implants of 18 plate dimensions and four
Publikováno v:
Der Unfallchirurg. 110:1013-1020
Background Comminuted calcaneal fractures are a consequence of high impact trauma to the foot. Stable fixation and anatomically correct repositioning of the joint surfaces are often a problem. To improve fracture treatment, surgical techniques in com
Publikováno v:
Der Unfallchirurg. 110:425-432
Trotz der Anwendung intramedullarer Krafttrager zur Stabilisierung von trochantaren Frakturen ist die Komplikationsrate weiterhin hoch. Eine Hauptursache fur belastende Reeingriffe ist das Durchschneiden des Krafttragers durch die Spongiosa des Femur
Autor:
Michael Blauth, K. Sellenschloh, W. Rabl, B. Curda, Rainer Biedermann, Werner Schmoelz, A. Hennerbichler, Michael M. Morlock, Thomas Klestil, K. Schwieger
Publikováno v:
Archives of Orthopaedic and Trauma Surgery. 126:387-393
The aim of the present in vitro study was to evaluate migrational characteristics of cementless primary hip arthroplasty stems in combination with a diameter 50 mm head (hemiarthroplasty) and a diameter 28 mm head in and with a polyethylene cup (tota
Autor:
Markus A. Wimmer, M. Honl, K. Schwieger, Frank Lampe, C. H. Gauck, Michael M. Morlock, Ekkehard Hille
Publikováno v:
Der Orthopäde. 34:1131-1136
BACKGROUND Aim of this in-vitro study was to compare the hip cup placement for total hip replacement when using different navigation systems compared with the traditional, non-navigated technique. METHODS Five different navigation systems were used:
Publikováno v:
Biomedizinische Technik/Biomedical Engineering. 49:18-21
Working on bone is a major aspect of orthopaedic surgery. Despite its well-known appreciable thermal effects on the edges of the bone cut, the oscillating bone saw blade the oscillating saw remains the standard instrument both for cutting long bones
Autor:
Frank Lampe, Christian Gauck, Volker Carrero, S. Dries, K. Schwieger, Markus Quante, M. Honl, Michael M. Morlock, Ekkehard Hille, Oliver Dierk
Publikováno v:
The Journal of Bone and Joint Surgery-American Volume. 85:1470-1478
Robotic-assisted total hip replacement has become a common method of implantation, especially in Europe. It frequently has been postulated that robotic reaming would result in an improved clinical outcome due to the better fit of the prosthesis, but
Autor:
Oliver Dierk, A. Betthäuser, K. Schwieger, Michael M. Morlock, S. Dries, W. W. Höpker, M. Honl, H. Uebeyli, Volker Carrero, Ekkehard Hille, Reemt Rentzsch
Publikováno v:
Zeitschrift für Orthopädie und ihre Grenzgebiete. 141:322-327
AIM The selectivity of a water jet (WJ) is already used with clinical advantage in the surgery of liver, brain, kidney and herniated lumbar discs. The aim of the present study was to determine whether a WJ can be used for synovectomy without damaging
Autor:
F Pude, M. Honl, Ekkehard Hille, Sebastian P. M. Dries, Volker Carrero, Andrea Bluhm, Oliver Dierk, Reemt Rentzsch, Hartmut Louis, K. Schwieger, Michael M. Morlock
Publikováno v:
Biomedizinische Technik/Biomedical Engineering. 48:275-280
Conventional tools used in prosthetic revision surgery have a limited range of action within the narrow cement mantle. Water jet cutting technology permits tiny and precisely controlled cuts, and may therefore be an alternative method of bone cement