Zobrazeno 1 - 10
of 11
pro vyhledávání: '"Justin L. Bond"'
Autor:
M. Wetstein, Justin L. Bond, O. H. W. Siegmund, W. A. Worstell, Michael E. Stochaj, Evan Angelico, Jeffrey W. Elam, Melvin Aviles, Michael R. Foley, Bernhard W. Adams, Alexey Lyashenko, Henry J. Frisch, E. Spieglan, Till Cremer, Mark A. Popecki, Michael J. Minot, Camden Ertley, Anil U. Mane, A. Elagin
Publikováno v:
Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 936:527-531
We report performance results achieved for fully functional sealed Large Area Picosecond Photodetectors (LAPPD™) in tests performed at Incom Inc., as well as independent test results reported by our early adopters. The LAPPD is a microchannel plate
Autor:
Bernhard W. Adams, Camden Ertley, Aileen O'Mahony, L. M. Kistler, C. A. Craven, Michael E. Stochaj, Michael J. Minot, Jeffrey W. Elam, M. S. Granoff, Justin L. Bond, Anil U. Mane, Till Cremer, Alexey Lyashenko, Michael R. Foley, W. A. Worstell, Melvin Aviles, O. H. W. Siegmund, Mark A. Popecki
Publikováno v:
Journal of Geophysical Research: Space Physics. 121:7449-7460
Microchannel plates (MCPs) have been used for many years in space flight instrumentation as fast, lightweight electron multipliers. A new MCP fabrication method combines a glass substrate composed of hollow glass capillary arrays (GCAs) with thin fil
Autor:
Justin L. Bond, Melvin Aviles, W. A. Worstell, M. Wetstein, Michael R. Foley, Jeffrey W. Elam, Lei Xia, Michael E. Stochaj, Oswald H. W. Siegmund, Ed May, Mark A. Popecki, A. Elagin, C. A. Craven, Junqi Xie, Henry J. Frisch, Alexey Lyashenko, Robert Wagner, Jingbo Wang, Michael J. Minot, Till Cremer, Camden Ertley, Anil U. Mane, Bernhard W. Adams
Publikováno v:
Springer Proceedings in Physics ISBN: 9789811313158
Recent performance results are presented for Large Area Picosecond Photodetectors (LAPPDTMs) being developed by Incom, Inc. The LAPPD is a micro-channel plate (MCP) based photodetector containing a bi-alkali photocathode with overall dimensions of 23
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::75133147705b02fe1e39c43a906a0ddc
https://doi.org/10.1007/978-981-13-1316-5_60
https://doi.org/10.1007/978-981-13-1316-5_60
Autor:
Camden Ertley, Justin L. Bond, Till Cremer, Bernhard W. Adams, Oswald H. W. Siegmund, Mark A. Popecki, W. A. Worstell, Michael R. Foley, Michael E. Stochaj, Melvin Aviles, Alexey Lyashenko, Jeffrey W. Elam, Michael J. Minot, Anil U. Mane, C. A. Craven
Publikováno v:
UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XX.
Atomic layer deposition (ALD) has enabled the development of a new technology for fabricating microchannel plates (MCPs) with improved performance that offer transformative benefits to a wide variety of applications. Incom uses a “hollow-core” pr
Autor:
Oswald H. W. Siegmund, W. A. Worstell, Michael R. Foley, Alexey Lyashenko, Michael J. Minot, Anil U. Mane, Camden Ertley, C. A. Craven, Mark A. Popecki, Bernhard W. Adams, Till Cremer, Jeffrey W. Elam, Justin L. Bond, Michael E. Stochaj
Publikováno v:
UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XX.
Microchannel plates have been made by combining glass capillary substrates with thin films. The films impart the resistance and secondary electron emission (SEE) properties of the MCP. This approach permits separate choices for the type of glass, the
Autor:
W. A. Worstell, Alexey Lyashenko, Melvin Aviles, Michael R. Foley, Till Cremer, Michael Stokaj, Bernhard W. Adams, Mark A. Popecki, Justin L. Bond, C. A. Craven, Henry J. Frisch, Evan Angelico, Michael J. Minot
Publikováno v:
Proceedings of 38th International Conference on High Energy Physics — PoS(ICHEP2016).
Autor:
Justin L. Bond, Klaus Attenkofer, C. A. Craven, Aileen O'Mahony, Mark A. Popecki, Michael J. Minot, Bernhard W. Adams, Till Cremer
Publikováno v:
SPIE Proceedings.
Bundles of hollow glass capillaries can be tapered to produce quasi-focusing x-ray optics. These optics are known as Kumakhov lenses. These optics are interesting for lab-based sources because they can be used to collimate and concentrate x-rays orig
Autor:
Jeffrey W. Elam, C. A. Craven, Melvin Aviles, A. Elagin, W. A. Worstell, Bernhard W. Adams, Camden Ertley, Justin L. Bond, Oswald H. W. Siegmund, Alexey Lyashenko, Till Cremer, Henry J. Frisch, Michael E. Stochaj, Michael J. Minot, Anil U. Mane, Mark A. Popecki, Michael R. Foley
Publikováno v:
SPIE Proceedings.
We report pilot production and advanced development performance results achieved for Large Area Picosecond Photodetectors (LAPPD). The LAPPD is a microchannel plate (MCP) based photodetector, capable of imaging with single-photon sensitivity at high
Autor:
Michael E. Stochaj, Joseph M. Renaud, Aileen O'Mahony, A. Elagin, C. A. Craven, R. Northrop, Karen Byrum, Michael J. Minot, M. Wetstein, A. Mane, Oswald H. W. Siegmund, Robert Wagner, Jeffrey W. Elam, Justin L. Bond, Jason B. McPhate, Henry J. Frisch, Daniel C. Bennis
Publikováno v:
Proceedings of Technology and Instrumentation in Particle Physics 2014 — PoS(TIPP2014).
Manufacturing plans for “next generation” microchannel plates (MCPs) and the technical advantages enabled by this evolving technology are presented. The Large Area Picosecond Photodetector (LAPPD) is an MCP based photodetector, capable of imaging
Autor:
Justin L. Bond, Chetan S. Sankar
Publikováno v:
Communications in Computer and Information Science ISBN: 9783642336805
In many technical disciplines, employers have suggested that insufficient focus has been given to the professional skills of students. In recent years, accrediting agencies and members of industry have emphasized the importance of these skills for te
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_________::e190c9021c48c461b854401486e3cea3
https://doi.org/10.1007/978-3-642-33681-2_12
https://doi.org/10.1007/978-3-642-33681-2_12