Zobrazeno 1 - 9
of 9
pro vyhledávání: '"Jure Jug"'
Publikováno v:
Zdravniški Vestnik, Vol 87, Iss 3-4 (2018)
Introduction: Occurrence of tachycardias increase during pregnancy in line with the increased propensity to ectopic activity. Case presentation: We present a case of a 30-year-old woman in the 18th week of pregnancy with atrial tachycardia and tachy
Externí odkaz:
https://doaj.org/article/3bcb68b880fd432db985825a9b2a4012
Publikováno v:
Zdravniški Vestnik, Vol 86, Iss 3-4 (2017)
We present a case of para-Hisian accessory pathway ablation in a patient with Wolff-Parkinson-White syndrome, which was performed with cryoablation to reduce the possibility of collateral damage to the conduction system of the heart. We also used
Externí odkaz:
https://doaj.org/article/9a375fd0f3e340f48385206e0ce480dd
Publikováno v:
Interact Cardiovasc Thorac Surg
OBJECTIVES Prolonged operative times, potentially leading to increased morbidity, are a possible drawback of minimally invasive aortic valve replacement. The aim of this study was to assess the impact of anatomical circumstances in the chest on aorti
Publikováno v:
Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery. 15:449-455
Objective Cardiac conduction system disturbances potentially leading to permanent pacemaker implantation are significant postoperative complications after aortic valve replacement. The aim of this study was to assess the impact of sutureless prosthet
Publikováno v:
Zdravniški Vestnik, Vol 87, Iss 3-4 (2018)
Introduction: Occurrence of tachycardias increase during pregnancy in line with the increased propensity to ectopic activity.Case presentation: We present a case of a 30-year-old woman in the 18th week of pregnancy with atrial tachycardia and tachyca
Publikováno v:
Zdravniški Vestnik, Vol 86, Iss 3-4 (2017)
We present a case of para-Hisian accessory pathway ablation in a patient with Wolff-Parkinson-White syndrome, which was performed with cryoablation to reduce the possibility of collateral damage to the conduction system of the heart. We also used
Anatomical circumstances and aortic cross-clamp time in minimally invasive aortic valve replacement.
Publikováno v:
Interactive Cardiovascular & Thoracic Surgery; Feb2021, Vol. 32 Issue 2, p204-212, 9p
Publikováno v:
Innovations: Technology & Techniques in Cardiothoracic & Vascular Surgery; Sep/Oct2020, Vol. 15 Issue 5, p449-455, 7p
Supplemental material, Visual Abstract, for Oversizing Increases Pacemaker Implantation Rate After Sutureless Minimally Invasive Aortic Valve Replacement by Borut Geršak, Mattia Glauber, Denis Bouchard, Jure Jug and Marco Solinas in Innovations: Tec
Externí odkaz:
https://explore.openaire.eu/search/publication?articleId=doi_dedup___::392c1ab9366c3a231316f66e5a84d241