Zobrazeno 1 - 10
of 120
pro vyhledávání: '"Jung-Hoon Ro"'
Autor:
Eui-Suk Sung, Hyun-Keun Kwon, Sung-Chan Shin, Young-Il Cheon, Jung-Woo Lee, Da-Hee Park, Seong-Wook Choi, Hwa-Bin Kim, Hye-Jin Park, Jin-Choon Lee, Jung-Hoon Ro, Byung-Joo Lee
Publikováno v:
Clinical and Experimental Otorhinolaryngology, Vol 14, Iss 1, Pp 131-136 (2021)
Objectives Facial nerve monitoring (FNM) can be used to identify the facial nerve, to obtain information regarding its course, and to evaluate its status during parotidectomy. However, there has been disagreement regarding the efficacy of FNM in redu
Externí odkaz:
https://doaj.org/article/769bcc612efa4f1eb1689ff5e06dc299
Autor:
Eui-Suk Sung, Sung-Chan Shin, Hyun-Keun Kwon, Jia Kim, Da-Hee Park, Seong-Wook Choi, Sang-Hoon Kim, Jin-Choon Lee, Jung-Hoon Ro, Byung-Joo Lee
Publikováno v:
Clinical and Experimental Otorhinolaryngology, Vol 13, Iss 3, Pp 291-298 (2020)
Objectives The loss of signal during intraoperative neuromonitoring (IONM) using electromyography (EMG) in thyroidectomy is one of the biggest problems. We have developed a novel IONM system with an endotracheal tube (ETT) with an attached pressure s
Externí odkaz:
https://doaj.org/article/2c1a73bfee4f4452b8ea6500869dcf3b
Autor:
Eui-Suk Sung, Jin-Choon Lee, Sung-Chan Shin, Hyun-Keun Kwon, Han-Seul Na, Da-Hee Park, Seong-Wook Choi, Jung-Hoon Ro, Byung-Joo Lee
Publikováno v:
Clinical and Experimental Otorhinolaryngology, Vol 12, Iss 4, Pp 420-426 (2019)
Objectives. The sensitivity and positive predictive value of widely used intraoperative neuromonitoring (IONM) using electromyography (EMG) of the vocalis muscle in thyroid surgery are controversial. Thus, we developed a novel IONM system with an acc
Externí odkaz:
https://doaj.org/article/e6ab5888abaa45188a51332a60dd2bd4
Autor:
Eui-Suk Sung, Jin-Choon Lee, Sung-Chan Shin, Hyun-Geun Kwon, Min-Sik Kim, Dong-Jo Kim, Jung-Hoon Ro, Byung-Joo Lee
Publikováno v:
Clinical and Experimental Otorhinolaryngology, Vol 12, Iss 2, Pp 217-223 (2019)
Objectives False-negative or false-positive responses in intraoperative neuromonitoring (IONM) using electromyography (EMG) in thyroid surgery pose a challenge. Therefore, we developed a novel IONM system that uses a surface pressure sensor instead o
Externí odkaz:
https://doaj.org/article/611e874d9f0441d0b83eb45e31b26307
Autor:
Young-Ok Lee, Byoung-Chul Kim, Jung-Hoon Lee, Jin-Choon Lee, Byung-Joo Lee, Soo-Geun Wang, Jung-Hoon Ro, Gye-Rok Jeon, Bum-Joo Shin
Publikováno v:
Clinical and Experimental Otorhinolaryngology, Vol 4, Iss 4, Pp 199-203 (2011)
ObjectivesThe objective of this study was to develop a new device that provides a simple, noninvasive method of measuring accurate lesion size while using an endoscope.MethodsWe developed a rigid laryngoscope with a built-in laser-ruler using a one-l
Externí odkaz:
https://doaj.org/article/ee48f5ec2dbb4414bd5c1f05cd9f01b7
Publikováno v:
Clinical and Experimental Otorhinolaryngology, Vol 2, Iss 4, Pp 186-192 (2009)
ObjectivesThis study investigated the telomerase expression in peripheral blood mononuclear cells (PBMCs) and the relationship between the serum level of several soluble factors such as vascular endothelial growth factor (VEGF), hepatocyte growth fac
Externí odkaz:
https://doaj.org/article/1362f8456d824041a748d2a359084daf
Publikováno v:
Journal of The Korean Society of Laryngology, Phoniatrics and Logopedics. 32:15-23
Autor:
Sung-Chan Shin, Hyo-Beom Jang, Jin-Choon Lee, Jung-Woo Lee, Jung Hoon Ro, Hyun-Keun Kwon, Eui-Suk Sung, Yeon Woo Lee, Byung-Joo Lee
Publikováno v:
Asian Journal of Surgery, Vol 44, Iss 1, Pp 153-157 (2021)
Objective This study aimed to demonstrate the usefulness of an attachable magnetic nerve stimulator for preservation of the external branch of the superior laryngeal nerve (EBSLN) during thyroidectomy. Methods We retrospectively analyzed 120 female p
Autor:
Da-Hee Park, Jung Hoon Ro, Sung-Chan Shin, Han-Seul Na, Seong-Wook Choi, Byung-Joo Lee, Jin-Choon Lee, Hyun-Keun Kwon, Eui-Suk Sung
Publikováno v:
Clinical and Experimental Otorhinolaryngology
Clinical and Experimental Otorhinolaryngology, Vol 12, Iss 4, Pp 420-426 (2019)
Clinical and Experimental Otorhinolaryngology, Vol 12, Iss 4, Pp 420-426 (2019)
Objectives The sensitivity and positive predictive value of widely used intraoperative neuromonitoring (IONM) using electromyography (EMG) of the vocalis muscle in thyroid surgery are controversial. Thus, we developed a novel IONM system with an acce
Autor:
Byung-Joo Lee, Dong-Jo Kim, Hyun-Geun Kwon, Jin-Choon Lee, Sung-Chan Shin, Jung Hoon Ro, Min-Sik Kim, Eui-Suk Sung
Publikováno v:
Clinical and Experimental Otorhinolaryngology, Vol 12, Iss 2, Pp 217-223 (2019)
Clinical and Experimental Otorhinolaryngology
Clinical and Experimental Otorhinolaryngology
Objectives False-negative or false-positive responses in intraoperative neuromonitoring (IONM) using electromyography (EMG) in thyroid surgery pose a challenge. Therefore, we developed a novel IONM system that uses a surface pressure sensor instead o